Maintenance-Object Repair Procedures
555-233-143
8-1360
Issue 1 May 2002
Analog Ring Generator Initialization Test (#117)
The Analog Ring Generator Initialization test sends a request to the active TN768,
TN780, TN2182 Tone-Clock or TN2312AP IPSI circuit pack’s Tone-Clock circuit to
monitor the voltage. The Tone-Clock responds with an error if the ringing voltage
falls too low.
Table 8-553.
Test #117 Analog Ring Generator Initialization Test
Error
Code
Test
Result
Description / Recommendation
1,
1000,
1001,
1003,
1115,
2012,
2100
ABORT
The system software is unable to determine the active Tone-Clock circuit pack,
unable to allocated the resources necessary to run the test, or unable to send a
down link message.
1. Wait for the green LED on the active Tone-Clock to go out; use the status
port-network command to determine the active Tone-Clock circuit pack.
2. Rerun the test. If the test aborts again, see
2000
ABORT
Response to the request was not received within the allowable time period.
1. Look for TDM-CLK errors and alarms. Resolve every other Tone-Clock
problem first.
2. Rerun the test.
PASS
The active Tone-Clock has successfully been enabled to monitor the ringing
voltage level.
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...