Additional Maintenance Procedures
555-233-143
5-38
Issue 1 May 2002
Test Call Results
■
If the test call successfully completes, and every trunk tests within
administered thresholds for marginal and unacceptable performance, then
a PASS result is returned.
■
If the test aborts or fails, an error code indicating the cause is returned.
The error codes are explained in the CO-TRK and TIE-TRK sections of
‘‘ABRI-PORT (ASAI ISDN-BRI Port)’’ on page 8-3
.
■
When the trunk is being used for call processing, the test aborts.
■
When the trunk is already being tested by maintenance software, the test is
queued and run when the maintenance activity finishes.
Measurement data gathered by analog testcalls can be retrieved with the list
testcalls command as described in
‘‘ATMS Reports (List Testcall Command)’’ on
. The measurements that are made and recorded depend on the type
of test that is specified and the capabilities of the far-end TTL.
shows a typical result for test analog-testcall trunk 60
Screen 5-1.
Test Results for test analog-testcall trunk 60
test analog-testcall trunk 60
TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
02B1901 TIE-TRK 060/001 845 PASS
02B1902 TIE-TRK 060/002 845 PASS
02B1903 TIE-TRK 060/003 845 PASS
02B1904 TIE-TRK 060/004 845 ABORT 1004
02B1905 TIE-TRK 060/005 845 PASS
02B1906 TIE-TRK 060/006 845 ABORT 1004
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...