Terminal Alarm Notification
Issue 1 May 2002
6-3
555-233-143
Terminal Alarm Notification
Terminal alarm notification is an optional feature which displays several types of
alarms on voice terminals with administered feature buttons or the attendant
console. A maximum of 10 digital and/or hybrid voice terminals may be used.
When an alarm occurs, the green status LED associated with the assigned button
will be in a steady state. The LED may be turned off by pressing the button
associated with the lighted alarm LED. If the LED is turned off and the alarm has
not been resolved by the time maintenance reschedules testing, the green status
LED will resume its steady state. The following alarms are displayed:
ac-alarm
Administered Connection alarm: A locally administered connection
(ADM-CONN) has a major, minor, or warning alarm active.
pr-awu-alm
Auto Wakeup Journal Printer alarm: The automatic wakeup journal
printer has a major, minor, or warning alarm active.
off-bd-alarm
DS1 or ATM Facility alarm: An off-board major, minor, or warning
alarm is active on a DS1-BD, UDS1-BD, or ATM-TRK board.
trk-ac-alm
Facility Access alarm: The facility access trunk test feature is
activated.
major-alrm
Major alarm: The system has logged a major alarm.
mj/mn-alrm
Major/Minor alarm: The system has logged a major or minor alarm.
pr-pms-alm
The Property Management System (PMS) printer has a major, minor,
or warning alarm active.
rs-alert
Reset-Alert: reset system 2 or 3 has been performed.
cdr1-alrm
Call Detail Recording alarm: The primary CDR link has a major,
minor, or warning alarm active.
cdr2-alrm
Call Detail Recording alarm: The secondary link has a major, minor,
or warning alarm active.
pr-sys-alm
System Printer alarm: The System Printer (SYS-PRNT) has a major,
minor, or warning alarm active.
pms-alarm
The Property Management System has a major, minor or warning
alarm active.
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...