Maintenance-Object Repair Procedures
555-233-143
8-1686
Issue 1 May 2002
Tone Generator Transmission Test (#40)
The purpose of this test is to verify that the tone generation hardware on the IPSI
or Tone-Clock circuit pack is capable of generating a subset of system tones and
a set of test tones. This test does not verify all system tones the tone generator
produces during normal system operation.
The test is performed in two parts. For the first part, the Tone Generator is told to
generate the touch-tone digits. The digits are received and checked by a Tone
Detector’s touch-tone detector. If any of the digits fail, the test is repeated using a
touch-tone detector in another Tone Detector circuit pack.
For the second part, the Tone Generator is told to generate call-progress tones
that are detected and identified by a tone detector. These tones are:
■
440 Hz
■
2225 Hz
■
Digital Count
The tone generator is then told to generate a sequence of test tones whose output
levels are measured by a tone detector. These tones are:
■
404 Hz at 0 dB
■
1004 Hz at -16 dB
■
1004 Hz at 0 dB
■
2804 Hz at 0 dB
A Tone Detector’s general-purpose tone detector listens for tones and measures
their quality. If any of the measured values are not within limits, the test is
repeated using a general-purpose tone detector in a different Tone Detector circuit
pack. If the values are still out of the limits, the test will fail.
For every failure case of Test #40, do the following:
1. Check that all Tone Detector circuit packs have the same companding
mode as that administered for the system. Correct the situation if there is a
mismatch.
2. Run the long test sequence: test tone-clock PC long repeat 1.
3. If the problem persists, replace the IPSI or Tone-Clock circuit pack by
following the steps outlined in
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...