UDS1-BD (UDS1 Interface Circuit Pack)
Issue 1 May 2002
8-1707
555-233-143
UDS1-BD (UDS1 Interface Circuit
Pack)
The UDS1 Interface circuit pack provides an interface to the DS1 facility.
The maintenance strategy for the TN464 UDS1 Interface circuit pack (UDS1-BD)
is very similar to the maintenance strategy for the TN767 DS1 Interface circuit
pack (DS1-BD). The same commands are used for administering and testing the
boards. The differences in maintenance strategy between the boards are due to
the UDS1 circuit pack’s direct interface to the Packet bus which is used for
ISDN-PRI signaling (ISDN-LNK). While both the TN464 and TN767 can support
ISDN-PRI B channels, ISDN-PRI D-channel signaling applications require a
TN464 UDS1 circuit pack. See the following table for a list of USD1 Interface
circuit packs:
UDS1 Interface circuit pack Maintenance documentation provides a strategy for
maintaining the UDS1 Interface circuit pack. The maintenance strategy deals with
logging the in-line errors reported by the UDS1 Interface circuit pack, running
tests for error diagnosis and recovery, and raising or clearing maintenance
alarms.
The TN464F or later circuit pack combined with an 120A1 CSU module forms an
Enhanced Integrated CSU. The 120A1 CSU module, when combined with the
functionality provided by the TN464F hardware and firmware, and switch
software, provides functionality equivalent to an external stand-alone ESF T1
CSU. The 120A1 CSU module connects to the TN464F circuit pack on the I/O
connector panel behind the port carrier. The CSU module, thus becomes an
integrated part of the S8700 Multi-Connect system. Throughout the document,
the term 120A1 will mean a 120A1 or later suffix CSU module.
MO’s Name
(in Alarm Log)
Alarm
Level
Initial SAT Command
to Run
1
1.
UU is the universal cabinet number (1–64 for ATM PNC, 1–44 for CSS PNC). C is the carrier designation (A,
B, C, D, or E). SS is the number of the slot where the circuit pack resides (01–21).
Full Name of MO
UDS1-BD
MAJOR
test board UUCSS sh
UDS1 Interface Circuit Pack
UDS1-BD
MINOR
test board UUCSS l
UDS1 Interface Circuit Pack
UDS1-BD
WARNING
test board UUCSS sh
UDS1 Interface Circuit Pack
Circuit Pack
Code
24
Channel
32
Channel
Tie Trunk
Signaling
CO Trunk
Signaling
DID
Trunk
Signaling
OPS Line
Signaling
TN2242
x
X
x
TN464C/D/E/F
x
x
x
x
x
x
(24-chl only)
TN2464
X
X
X
X
X
X
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...