VAL-BD (Voice Announcements over LAN Circuit Pack)
Issue 1 May 2002
8-1835
555-233-143
Table 8-701.
TN2501AP LEDs
LED
Behavior
Description
Red
On solid
Circuit pack failure or a major or minor on-board alarm
Green
On solid
Firmware is self-downloading to the circuit pack or testing in progress.
Amber
On solid
Firmware is self-downloading to the circuit pack.
!
CAUTION:
You can lose the resident firmware image file if you reset the
circuit pack during firmware download. If this happens, FTP
a new firmware image file to the VAL circuit pack and
perform the Firmware download procedure again.
Amber
Fast flash
(100 ms on/
100 ms off)
Occurs during circuit pack insertion or circuit pack reset which the
announcement files are being copied from FLASH to RAM. If you reset
the circuit pack during this time, your announcement files remain intact.
Amber
Slow flash
(200 ms on/
200 ms off)
Flashes during autosave while copying announcement files from RAM to
FLASH.
!
CAUTION:
You can lose the announcements on the circuit pack if you
reset it during an autosave.
LINK
On/off
Active Ethernet link
TRMT
Intermittent
Transmit
RCV
Intermittent
Receive
100M
On/off
Off = 10-Mbps Ethernet connection
On = 100-Mbps Ethernet connection
FDX
On/off
Off = half-duplex connection
On = full-duplex connection
COL
On/off
Off = no collisions detected
On = collisions detected
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...