change fiber-link
Issue 1 May 2002
7-61
555-233-143
change fiber-link
change fiber-link fiber#
NOTE:
This command is not valid for S8700 IP Connect configurations.
The change fiber-link command changes the translation data associated with an
existing fiber link. On critical-reliability systems (duplicated PNC), each fiber link
is duplicated and exists as a pair. When PNC duplication is enabled, only the
fields on pages 2 and 3 (the DS1 CONV complex attributes) can be changed.
Translation data is not changed until the
Enter
key is pressed. Pressing
CANCEL
any time before pressing E
NTER
to enter the changes returns you to the command
line without changing any translation data.
When you enter a command that changes translation data, two checks are made:
■
You must have permission to administer the feature.
■
No other user may be executing a
change, add, or remove fiber-link
command.
To change the endpoint board locations, you must remove a fiber and add it again
for either a:
■
High-reliability system (unduplicated PNC)
■
Critical-reliability system with a fully operational duplicated PNC
Parameters
Examples
change fiber-link 21
number
The administered number (1–44) associated with a fiber link or, on a duplicated PNC,
with a fiber link pair.
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...