Maintenance Commands
555-233-143
7-382
Issue 1 May 2002
status sp-link
status sp-link [print]
This command displays a summary of the operational state of the system printer
link.
Output
The following display shows a typical result when
status sp-link is entered.
Field Descriptions
Link State:
The operational state of the link:
■
up
— A call is currently set up to the system printer.
■
down
— The link is administered but a call is not currently set up to the
printer.
■
extension not administered
— An extension has not been
administered for the system printer on the features-related system
parameters form.
Number of
Retries:
The number of times the switch has tried to establish the link since a request to
set it up has been received. This field is displayed only when the link is down.
The maximum value displayed is 999.
Maintenance
Busy?
Whether maintenance testing is being performed on the system printer link. A
blank is displayed if the system printer link is not administered.
status sp-link
SYSTEM PRINTER LINK STATUS
Link State: down
Number of Retries: 0
Maintenance Busy? no
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...