test ds1-loop
Issue 1 May 2002
7-425
555-233-143
test ds1-loop
test ds1-loop – For TN464F or TN767E or later suffix DS1 Interface circuit packs.
This command is used for loopback and one-way span testing of the DS1 span.
Synopsis
test ds1-loop location [cpe-loopback-jack-test-begin [number-of-bits
bit-pattern] | far-csu-loopback-test-begin | one-way-span-test-begin |
end-loopback/span-test | inject-single-bit-error | ds1/csu-loopback-tests]
Permissions
Logins with the following service levels may execute this command: system
technician, inads, init, super-user, or logins with Maintain Switch Circuit Packs
permissions enabled.
Examples
test ds1-loop 01c08
test ds1-loop 1-3c03 cpe-loopback-jack
test ds1-loop 1-3c03 cpe
test ds1-loop 10c03 end
test ds1-loop 02d12 fa
test ds1-loop 02d12 inj
Description
The test ds1-loop command will validate that the board exists at the specified
location, that the board is a TN464F or TN767E or later suffix DS1 Interface
board. Based on the command parameter, a long-duration loopback/span test or
series of short-duration loopback tests will be executed.
Long-duration loopback tests execute for an extended period of time until the
system technician terminates it. Short-duration loopback tests return the result of
the test to the screen when finished executing. The list measurements ds1
summary command should be used to monitor the status of a long-duration
loopback/span test.
Defaults
The default for the command is ds1/csu-loopback-tests.
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...