Maintenance Commands
555-233-143
7-432
Issue 1 May 2002
test environment
test environment UU [short | long] [repeat# | clear] [schedule]
The test environment command performs hardware diagnostic tests of the
environment monitoring and control, and emergency transfer functions of a
specified cabinet. This command tests EPN cabinets. Circuit packs involved are
the EPN’s Maintenance and Tone-Clock (for the ring generator test).
!
CAUTION:
The long test recycles power on every port circuit pack carrier and is
destructive. It does not recycle power on active or standby EPN control or
switch node carriers. When a port carrier is recycled, all service and links to
ports on the carrier are dropped. If a carrier containing an active EI or
Tone-Clock is recycled, all service to that cabinet will be disrupted.
There are 10 Maintenance Objects involved in this test:
Note that although the CUST-ALARM maintenance object is part of the
environment functionality, it is not actually tested using the ‘test maintenance’
command. See ‘test customer-alarm’ for details on testing this particular MO.
NOTE:
A new MO, RMC-ENV, displays when the rack mount cabinet is used for the
S8700 IP Connect.
EMG-XFER
CABINET
AC-POWER
RING-GEN
CARR-POW
CUST-ALARM
POWER
EXT-DEV
DC-POWER
RMV-GEN
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...