ABRI-PORT (ASAI ISDN-BRI Port)
Issue 1 May 2002
8-3
555-233-143
ABRI-PORT (ASAI ISDN-BRI Port)
For repair procedures, see
‘‘BRI-PORT (ISDN-BRI Port), ABRI-PORT (ASAI
ISDN-BRI Port)’’ on page 8-330
.
MO’s Name (in
Alarm Log)
Alarm Level
Initial Command to Run
Full Name of MO
ABRI-PORT
1
1.
The alarm level for ABRI ports may be administered using the set options command. The alarm
level can be set independently for on- and off-board alarms to WARNING, MINOR, or MAJOR for
every ABRI port in the system.
MAJOR
MINOR
WARNING
test port UUCSSpp l
2
2.
UU is the universal cabinet number (1–64 for ATM PNC, 1–44 for CSS PNC). C is the carrier
designation (A, B, C, D, or E). SS is the number of the slot where the circuit pack resides (01–21).
pp is the 2-digit port number (01, 02, 03 ...).
ASAI ISDN-BRI port