AC-POWER
Issue 1 May 2002
8-9
555-233-143
AC-POWER for DC-Powered Systems
NOTE:
In a DC-powered multicarrier cabinet, the AC-POWER MO exists, but
serves no functional purpose. Because the system cannot determine the
type of power used, the AC-POWER test should always pass or abort. The
maintenance strategy for power components in DC cabinets is described in
‘‘CARR-POW (Carrier Power Supply)’’ on page 8-393
S8700 Multi-Connect supports three different cabinet types for EPNs: multicarrier
cabinets (MCCs), single-carrier cabinets (SCCs), and 19-inch rack mounted
cabinets. Every type may be powered by either an AC or DC power source.
Environmental maintenance differs according to a cabinet’s type and its power
supply.
Error Log Entries and Test to Clear Values
MO’s Name (in
Alarm Log)
Alarm
Level
Initial Command to Run
Full Name of MO
AC-POWER
WARNING
test environment UU
1
1.
UU is the universal cabinet number (1–64 for ATM PNC, 1–44 for CSS PNC).
AC Power
Table 8-3.
AC Power Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Of
f
Board
Test to Clear Value
0
1
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test’s description, and follow its recommended procedures.
0
Any
Any
Any
test environment UU sh r 1
513
Any
AC Power Query test (#78)
WARNING
OFF
test environment UU sh r 1
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...