ADX8D-BD (AUDIX Circuit Pack)
Issue 1 May 2002
8-15
555-233-143
ADX8D-BD (AUDIX Circuit Pack)
The ADX8D-BD MO represents a TN566/TN2169 EMBEDDED AUDIX circuit
pack (also called DEFINITY AUDIX) operating in DP (digital-port) mode. For
circuit-pack-level problems, see
‘‘XXX-BD (Common Port Circuit Pack)’’ on page
. Port-level problems are covered by ADX8D-PT.
EMBEDDED AUDIX
consists of two circuit packs that occupy 5 slots on a port
carrier. The tests described in this manual apply only to switch-side maintenance
which tests a circuit pack’s components related to the TDM-bus interface. The
AUDIX system has an extensive maintenance strategy that is described in
EMBEDDED AUDIX System Maintenance, 585-300-110.
MO’s Name (in
Alarm Log)
Alarm Level
Initial Command to Run
1
1.
UU is the universal cabinet number (1–64 for ATM PNC, 1–44 for CSS PNC). C is the carrier
designation (A, B, C, D, or E). SS is the number of the slot where the circuit pack resides (01–21).
Full Name of MO
ADX8D-BD
MINOR or
WARNING
test board UUCSS sh
AUDIX circuit pack