Maintenance-Object Repair Procedures
555-233-143
8-82
Issue 1 May 2002
Hardware Error Log Entries and Test to Clear
Values
Notes:
a. These are in-line errors that can only be resolved over time.
Aux Data 40960 Indicates that too many simultaneous incoming ringing
attempts were made on this board. Only 4 ports on a board may ring
simultaneously. A 5
th
incoming call will cause an inline error from the
board.
Aux Data 40975 indicates that the terminal equipment was on-hook when
ring-tip was detected during ringing. This usually indicates a failure in the
terminal equipment or the type of terminal has a low ringer impedance.
Table 8-33.
8-Port Analog Line Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test’s description, and follow its recommended procedures.
0
Any
Any
Any
test port UUCSSpp sh r 1
1 (a)
40960
40977
40975
None
15 (b)
Any
Audits and Updates
test (#36)
18
0
busyout station
extension
WARNING
OFF
release station extension
130 (c)
None
WARNING
ON
test port UUCSSpp sh
257 (d)
Station Present test
(#48)
WARNING
OFF
test port UUCSSpp sh r 3
513
Battery Feed test
(#35)
MINOR
WARNING
2
2.
Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the set options
command.
ON
test port UUCSSpp sh r 2
769 (e)
Loop Around and
Conference test
(#47)
test port UUCSSpp l r 3
1025
NPE Crosstalk test
(#6)
MINOR
WARNING
ON
test port UUCSSpp l r 3
1281 (f)
1793 (f)
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...