Maintenance-Object Repair Procedures
555-233-143
8-128
Issue 1 May 2002
Angel-Speech Processor Handshake Test (#208)
This test checks the integrity of the communication link between the two
processors on the Announcement circuit pack.
!
CAUTION:
Failure of this test indicates that the Speech Processor is insane and results
in the loss of every integrated announcement on the circuit pack.
Table 8-47.
Test #208 Angel-Speech Processor (SP) Handshake Test
Error
Code
Test
Result
Description / Recommendation
2000
ABORT
Response to the test request was not received within the allowable time period.
If Error Type 1538 is present in the Error Log, follow the maintenance strategy
recommended for this Error Type.
2100
ABORT
Could not allocate the necessary system resources to run this test.
ABORT
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
The circuit pack cannot be used. Announcement speech memory is cleared
when this test fails. When the problem has been resolved, announcements
must be re-recorded or downloaded to the circuit pack. Refer to Essential
Service Information earlier.
1. Reset the circuit pack by the reset board UUCSS command and then run
this test again. If the test continues to fail, replace the circuit pack.
2. If there are recurring alarms on this circuit pack caused by this test failing,
replace the circuit pack, even if step 1 works.
!
CAUTION:
Replacing the circuit pack causes a loss of integrated announcements.
Refer to
‘‘Essential Service Information’’ on page 8-120
of the AN-LN-PT
MO.
PASS
The communications link between the two processors on the announcement
circuit pack is functioning properly. User-reported troubles on this circuit pack
should be investigated using other circuit pack and port tests. Refer to
“ANN-PT” for a description of the port tests.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...