ANN-BD (Announcement Circuit Pack)
Issue 1 May 2002
8-129
555-233-143
Announcement Checksum Test (#209)
In this test, the Speech Processor calculates a global checksum covering the
entire announcements file and compares it to a stored one. If the comparison of
any announcement’s checksum fails, then the total number of defective
announcements found is reported. The test failure is associated with an error
type 14 in the Error Log. The aux data gives the identifying number of the first
defective announcement found. This number and the extension assigned to the
announcement are listed on the display announcement command.
Table 8-48.
Test #209 Announcement Checksum Test
Error
Code
Test
Result
Description / Recommendation
1023
ABORT
There are no announcements currently recorded on the circuit pack.
1024
ABORT
This abort code indicates any of the following:
■
An announcement upload or download is in progress.
■
An announcement upload or download was requested while the test was
running.
■
A recording session was in progress.
■
A recording session was initiated in while this test was running.
If an announcement upload or download is in progress, status data-module
extension should show that the announcement data port (17) is connected to a
data line port that is part of a system port, and the removable media or disk
should be active. (To determine the extension of the announcement data
module, use the list data-module command.) See also
Announcement Circuit Pack’’ on page 8-131
.
1. Wait until the cause of the abort finishes, and run the test again. Upload or
download can take up to 45 minutes to complete. A recording session is
finished as soon as the station that was making the recording is placed
on-hook.
2. If the test continues to abort, and a recording session or upload/download
is not in progress, escalate the problem.
2000
ABORT
Response to the test request was not received within the allowable time period.
If Error Type 1538 is present in the Error Log, follow the maintenance strategy
recommended for this Error Type.
2100
ABORT
Could not allocate the necessary system resources to run test.
ABORT
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...