Troubleshooting a Duplicated Server
Issue 1 May 2002
4-13
555-233-143
Auxiliary Data for SYSTEM Errors 6002, 6003,
6102, and 6103
The following table shows which components are indicted by the auxiliary error
codes found by using the preceding flowchart (
). Once
you have identified the faulted component, consult the section for that
maintenance object (MO).
Testing the Standby Server
The server (system’s SPE) may not have had time to log errors against the failed
component that caused the spontaneous interchange. If you have progressed
through the preceding flowchart without determining the cause of interchange,
test the standby for faults by proceeding through the following steps shown in
.
Aux Data
Implicated MO
4137
PKT-INT
16389
DUPINT
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...