Installation Instructions for the TANDBERG 150 MXP - 
Issue 1.0 

 

Abstract 

 

 
These Installation Instructions detail steps for installing TANDBERG 150 MXP (T150) in the 
Avaya H.323 environment. This document is intended for use by Avaya service personnel.  
Procedures pertaining to the installation, initial configuration and troubleshooting of the T150 
are provided.  References to source TANDBERG documentation are provided as warranted for 
additional detailed information in these areas.  The information provided is relevant to the L5 
software release of T150 software configured for CM4.0. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Summary of Contents for Tandberg 150 MXP

Page 1: ...the Avaya H 323 environment This document is intended for use by Avaya service personnel Procedures pertaining to the installation initial configuration and troubleshooting of the T150 are provided References to source TANDBERG documentation are provided as warranted for additional detailed information in these areas The information provided is relevant to the L5 software release of T150 software ...

Page 2: ...fy Licensing 3 2 2 Configure Connectivity 4 2 3 Configure an H 323 Station to Support the Tandberg Centric 150 MXP 7 3 Tandberg System Connections 8 4 Tandberg Configuration 11 4 1 Manually Assign an IP Address 11 4 2 Configure the Tandberg Centric 150 MXP 12 5 Optional Features Settings 13 5 1 Date and Time Settings 13 6 Support 13 7 References 13 ...

Page 3: ...nfiguration displayed in these Application Notes If a required feature is not enabled or there is insufficient capacity contact an authorized Avaya account representative to make the appropriate changes Step Description 2 1 1 Issue the command display system parameters special applications and proceed to page 5 Verify that the SA8697 3rd Party H 323 Endpoint Support field is enabled display system...

Page 4: ...y Registered IP eCons 0 0 Max Concur Registered Unauthenticated H 323 Stations 100 0 Maximum Video Capable H 323 Stations 100 16 Maximum Video Capable IP Softphones 100 5 Maximum Administered SIP Trunks 800 225 Maximum Number of DS1 Boards with Echo Cancellation 0 0 Maximum TN2501 VAL Boards 10 0 Maximum Media Gateway VAL Sources 0 0 Maximum TN2602 Boards with 80 VoIP Channels 128 0 Maximum TN2602...

Page 5: ...e for recommendations on determining the LAN maximum call rate and for more details on priority video 8 Step Description 2 2 3 Issue the command change ip network region n where n is the number of an available IP network region and administer settings as displayed Enter the number of the IP codec set provisioned in Step 2 2 1 in the Codec Set field Use default settings for remaining fields change ...

Page 6: ...rency in Survivable Mode n BACKUP SERVERS IN PRIORITY ORDER H 323 SECURITY PROFILES 1 1 any auth 2 2 3 3 4 4 5 6 Allow SIP URI Conversion y TCP SIGNALING LINK ESTABLISHMENT FOR AVAYA H 323 ENDPOINTS Near End Establishes TCP Signaling Socket y Near End TCP Port Min 61440 Near End TCP Port Max 61444 Step Description 2 2 5 Proceed to Page 3 and enable inter region connectivity between IP network regi...

Page 7: ...e an H 323 Station to Support the Tandberg Centric 150 MXP This section describes the steps for configuring an H 323 station on Avaya Communication Manager to support the Tandberg Centric 150 MXP Step Description 2 3 1 Issue the command add station n where n is the extension of an available station and administer settings as displayed Repeat this step for each Tandberg Centric 150 MXP in the netwo...

Page 8: ...ck for a 10 100 Ethernet connection to an associated PC This jack is labeled PC and is just to the left of the Ethernet jack while looking at the bottom of the unit 4 Optional 2 5 mm 3 pole jack for a headset This jack is labeled with a headset symbol 5 Optional Modular handset jack This jack is labeled with a handset symbol Additional notes on the photographs are as follows The optional PC jack i...

Page 9: ...Issue 1 0 1 10 2008 2008 Avaya Inc All Rights Reserved 9 of 13 Figure 2 Keypad of TANDBERG 150 MXP Figure 3 Back Bottom View of TANDBERG 150 MXP ...

Page 10: ... and DHCP is enabled by default If use of DHCP is appropriate then the steps in this section would not be required Note IP address change requires a restart of the system and it could be difficult to recover from a configuration error if the change is performed over telnet Step Description 1 Press the Settings key on the T150 If prompted for the Administrator Password enter it using the numeric ke...

Page 11: ...tatically configured on the Tandberg Centric 150 MXP Establish a telnet session using the MS DOS telnet client supplying the IP Access Password when prompted Step Description 4 2 1 Log in to the Tandberg Centric 150 MXP with the appropriate credentials and enter the following commands as displayed The Tandberg Centric 150 MXP must be re booted to accept the administrative changes Note The commands...

Page 12: ...sp A phone number for support within the Americas is 866 826 3237 7 References The following are the source TANDBERG documents referenced in this document The documents are available from the TANDBERG web site at the associated URL 1 TANDBERG 150 MXP User Guide L5 0 Document D14067 01 May 2007 http www tandberg com collateral documentation User_Manuals TANDBERG 2015 0MXP 20User 20Manual 20 L5 pdf ...

Page 13: ...n Notes for Tandberg Polycom and Avaya Video Endpoitns with Avaya Communication Manager Utilizing H 323 Signaling Issue 1 0 7 Job Aid for the Tandberg 150 MXP Issue 1 0 8 Avaya Video telephony Networking Guide R3 http support avaya com elmodocs2 video_telephony 16_601423_1 pdf ...