AC OK (green)
DC OK (green)
Service (amber) Fault (red)
Condition
Off
On
Off
Off
No AC for less than 15 ms on
a single unit
blinks
Off
Off
Off
AC present but not within
limits
Off
Off
Off
Off
AC not present
On
Off
Off
On
Boost stage failure
On
Off
Off
On
Over voltage latched
shutdown
On
On
Off
On
Non-catastrophic internal
failure
On
Off
Off
Off
Standby
The 9080CP module also provides LEDs for the power supplies. Software on the 9080CP module
automatically determines whether you have installed the 9080CP module in the Virtual Services
Platform 9010 chassis or the Virtual Services Platform 9012 chassis. You do not have to update the
configuration.
The 9080CP module provides six LEDs for power supplies. The Virtual Services Platform 9010
chassis can use a maximum of eight power supplies. On the 9080CP module installed in a Virtual
Services Platform 9010 chassis, the LED for Auxiliary module 1 corresponds to power supply 7, and
the LED for Auxiliary module 2 corresponds to power supply 8.
For more information about the LEDs on the 9080CP module, see
Installing Modules in Avaya
Virtual Services Platform 9000,
NN46250-301.
Chassis and power supply compatibility
The following table indicates the compatibility between chassis and AC power supply models.
Table 2: Chassis and AC power supply compatibility
Power supply
VSP 9010AC chassis
VSP 9012 chassis
9006AC
Supported
Supported
AC power supply fundamentals
12
Installing AC Power Supplies in Avaya VSP 9000
December 2014