Parameter
Specification
Europe
ENIEC 60950-1 (CE Marking)
Australia/New Zealand
AS/NZS IEC 60950-1
Mexico
NOM
Korea
MIC
VSP 9012 chassis specifications
This section provides physical, environmental, and electrical specifications for the Virtual Services
Platform 9012 chassis.
Physical specifications
The following physical specifications apply to the chassis.
Table 25: VSP 9012 chassis physical specifications
Parameter
Specification
Height
24.375 in. (61.91 cm)
Rack units (RU)
14
Width
17.5 in. (44.45 cm)
Depth
32.5 in. (82.55 cm) plus cable
management system
Weight
Chassis and midplane
160 lb (73 kg)
Chassis and midplane, and cooling modules
183 lb (83 kg)
Network Equipment Building Standard
The Virtual Services Platform 9012 chassis does not comply with Network Equipment Building
Standard (NEBS) Level 3 as specified in SR3580.
Environmental specifications
The following environmental specifications apply to the chassis.
Table 26: VSP 9012 chassis environmental specifications
Parameter
Specification
Operating temperature (room or
ambient temperature)
0°C to 40°C (32°F to 104°F)
Operating temperature (high
altitude)
Decrease the high temperature value by 1.8 °F for each 1,000 feet (1
°C for each 305 meters) increase in altitude.
Storage temperature
– 25°C to 70°C (– 13°F to 158°F)
Table continues…
VSP 9012 chassis specifications
October 2015
Installing the Avaya VSP 9000