1-6
Introduction
VSU-10000 User Guide
SELV Circuit Warning
WARNING: The Ethernet 10/100/1000BASE-T, serial, console, and auxiliary
ports contain safety extra-low voltage (SELV) circuits. Do not connect to a
telephone line.
General Site Requirements
This section describes the requirements your site must meet for safe installation
and operation of your system. Ensure that your site is properly prepared before
beginning installation.
Environmental Requirements
The VSU-10000 is intended for use in a normal office environment. For more
extreme conditions, verify that temperature, humidity, and power conditions
meet the specifications indicated in Table 1-2.
Additional VSU-10000 specifications are included in Appendix A.
Site Power Considerations
Check the power at your site to ensure that you are receiving “clean” power (free
of spikes and noise). Install a power conditioner if necessary.
Table 1-2
Environmental Requirements
Item
Operating Specification
Temperature
32° to 104° F, 0° to 40°C
Relative Humidity
5-90%, non-condensing
Altitude
0-12,000 feet, 0-3,660 meters
Voltage
100-240 VAC
Input Frequency
50-60 Hz
AC input current
3.5 Amps