background image

3

Insert the Module

L

You should upgrade the P330 switch firmware and Embedded Web Manager to version 
3.12 or higher before installing the X330W-2USP module. 

To insert an X330W-2USP into an Avaya P330 switch:
1

Remove the blanking plate or installed expansion module.

2

Insert the WAN expansion module gently into the slot, ensuring that the Printed Circuit 
Board (PCB) is aligned with the guide rails.

L

The PCB fits into the guide rails and not the metal base plate.

3

Press in the expansion module firmly until it is completely inserted into the Avaya P330 
switch.

4

Gently tighten the two screws on the front panel of the expansion module by turning them 
clockwise.

5

Power up the Avaya P330 switch.

X

The self-test procedure starts. It takes between 30 to 60 seconds to complete.

X

The OPR LED on the X330W-2USP module should illuminate 55 seconds after startup.
The module is then ready for use.

L

You can now safely connect the cables to the unit.

Summary of Contents for X330W-2USP

Page 1: ...ule Unpack the Module Important Safety Information Note You should upgrade the P330 switch firmware and Embedded Web Manager to version 3 12 or higher before installing the X330W 2USP module If you ne...

Page 2: ...on To avoid damage from static only hold the WAN Expansion Router Module by the edges Do not touch the top or bottom of the circuit board If possible wear a wrist strap and use an anti static bag Caut...

Page 3: ...Documentation Avaya X330W 2USP WAN Access Router Modules Quick Start Guide this document Avaya X330W 2USP WAN Access Router Modules Release Notes Avaya X330WAN Documentation and Utilities CD Avaya War...

Page 4: ...igned with the guide rails L The PCB fits into the guide rails and not the metal base plate 3 Press in the expansion module firmly until it is completely inserted into the Avaya P330 switch 4 Gently t...

Page 5: ...tEthernet port to a PC or workstation you should use a crossed cable L If you are connecting the FastEthernet port to another switch you should use a straight cable Connecting the Console Port Each Av...

Page 6: ...a context type a question mark To display all commands starting with a certain string type the first few letters followed by a question mark To get help containing all commands parameters with their l...

Page 7: ...onnect via its console interface to the X330W 2USP L The console interface configured with the interface Console command must be on a different subnet from the router interfaces 6 Use the following co...

Page 8: ...that the running state is idle by entering the show copy status command 6 Reset the switch using the reset command Configuring FastEthernet Interfaces L All CLI commands mentioned in this section are...

Page 9: ...IP addresses 10 10 10 1 on VLAN 2 and 20 20 20 1 and 30 30 30 1 on VLAN 3 perform the following X330WAN 2USP 1 super interface FabricFastEthernet 1 2 X330WAN 2USP 1 super if FabricFastEthernet1 2 ip a...

Page 10: ...rame Relay L The default value for Frame Relay lmi type is auto learning supporting both Annex A Q933 and Annex D ANSI 7 Type exit to return to Supervisor mode 8 Use the interface serial if number if...

Page 11: ...2USP you chose If there is no response check the IP address and default gateway of both the X330W 2USP and the station 3 From the Microsoft Windows taskbar of your PC click Start and then Run or from...

Page 12: ...lt parameters we recommend that you use the CLI Please refer to the Avaya X330WAN User s Guide Function Default Setting Port speed FastEthernet 100 Mbps Port duplex FastEthernet Full Duplex Auto negot...

Page 13: ...ent interface pmi to the X330W 2USP module The default pmi is the first interface you define 1 Verify that there is communication between the Master Switch and the X330W 2USP using the ping command to...

Page 14: ...indows Explorer 4 Open the embweb aux files folder on the CD 5 Double click on the plugin_a_b_c exe file a b and c are the version numbers of the plug in 6 Follow the on screen instructions Or install...

Page 15: ...L Documentation and Online Help Refer to the Avaya X330WAN Documentation and Utilities CD for full instructions...

Page 16: ...756 800 Sweden 46 851 992 080 Czech Rep 31 70 414 8006 Luxemburg 352 29 6969 5624 Switzerland 41 22 827 8741 Denmark 45 8233 2807 Macedonia 31 70 414 8041 Tanzania 31 70 414 8060 Egypt 31 70 414 8008...

Reviews: