5
P
U T T I N G I N T O S E R V I C E
■
■
■
■
■
■
■
A I R S U P P L Y
All tools are operated with compressed air at an optimum pressure of 5.4 bar. We recommend the use of pressure regulators and
automatic oiling/filtering systems on the main air supply. These should be fitted within 3 metres of the tool (see diagram below) to ensure
maximum tool life and minimum tool maintenance.
Air supply hoses should have a minimum working effective pressure rating of 150% of the maximum pressure produced in the system
or 10 bar, whichever is the highest. Air hoses should be oil resistant, have an abrasion resistant exterior and should be armoured where
operating conditions may result in hoses being damaged. All air hoses MUST have a minimum bore diameter of 6.4 millimetres or
1
/
4
inch.
Read servicing daily details page 11.
O P E R A T I N G P R O C E D U R E
Ensure that the correct nose assembly is fitted.
Connect the tool to the air supply.
Push the Avdelok pin through the application hole .
Place the collar on the pin (orientation as shown right).
Keeping the head of the pin against the application, push the
tool onto the protruding pin tail.
Fully operate the trigger. One cycle will ensure that the collar
is swaged into the lock grooves of the pin and the pin breaks
at the breaker groove.
Release the trigger. The tool completes its cycle by pushing
itself off the collar and ejecting the pin tail at the rear.
8
6
4
2
0
10
12
14
16
TAKE OFF POINT
FROM MAIN SUPPLY
STOP COCK
(USED DURING MAINTENANCE
OF FILTER/REGULATOR
OR LUBRICATION UNITS)
MAIN SUPPLY
DRAIN POINT
PRESSURE REGULATOR
AND FILTER
(DRAIN DAILY)
LUBRICATOR