22
D a i l y
We e k l y
M o l y L i t h i u m G r e a s e E P 3 7 5 3 S a f e t y D a t a
S e r v i c i n g t h e To o l
I M P O R T A N T
The employer is responsible for ensuring that tool maintenance instructions are given to the appropriate personnel.
The operator should not be involved in maintenance or repair of the tool unless properly trained.
Grease can be ordered as a single item, the part number is shown in the service kit page 23.
First Aid
SKIN:
As the grease is completely water resistant it is best removed with an approved emulsifying skin cleaner.
INGESTION:
Ensure the individual drinks 30ml Milk of Magnesia, preferably in a cup of milk.
EYES:
Irritant but not harmful. Irrigate with water and seek medical attention.
Fire
FLASH POINT: Above 220°C.
Not classified as flammable.
Suitable extinguishing media: CO
2
,
Halon or water spray if applied by an experienced operator.
Environment
Scrape up for burning or disposal on approved site.
Handling
Use barrier cream or oil resistant gloves
Storage
Away from heat and oxidising agent.
Regular servicing should be carried out and a comprehensive inspection performed annually or every 500,000 cycles, whichever is
sooner.
•
Daily, before use or when first putting the tool into service. Pour a few drops of clean lubricating oil into the air inlet of the
intensifier if no lubricator is fitted on air supply. If the tool is in continuous use, the air hose should be disconnected from the main
air supply and the tool lubricated every two to three hours.
•
Check for air and oil leaks. If damaged, hoses and couplings should be replaced.
•
If there is no filter on the pressure regulator, bleed the airline to clear it of accumulated dirt or water before connecting the air
hose to the intensifier. If there is a filter, drain it.
•
Check that the nose equipment is correct.
•
Check mandrels regularly for signs of wear or damage monitoring the number of placings (read the safety instructions on page 4).
•
Conduct the full “Daily” procedures as described above.
•
Remove, inspect, clean and grease the Tail Jaws (refer to “Tail Jaw Cylinder” in the "Maintenance Section" page 24).
•
Check oil level in the intensifier Unit reservoir is approximately 12mm (
1
/
2
”) below the transparent cover plate.
Summary of Contents for 0753 MkII
Page 2: ......
Page 38: ...38 Notes...