10
Servicing the Tool
Regular servicing should be carried out and a comprehensive inspection performed annually or every 500,000 cycles, whichever is sooner.
I M P O R T A N T
Read Safety Instructions on page 4.
The employer is responsible for ensuring that tool maintenance instructions are given to the appropriate personnel.
The operator should not be involved in maintenance or repair of the tool unless properly trained.
The tool shall be examined regularly for damage and malfunction.
Daily
•
Daily, before use or when first putting the tool into service, pour a few drops of clean, light lubricating oil into the air inlet of the tool if no
lubricator is fitted on air supply. If the tool is in continuous use, the air hose should be disconnected from the main air supply and the tool
lubricated every two to three hours.
•
Check for air leaks. If damaged, hoses and couplings should be replaced.
•
Check for oil leaks.
•
If there is no filter on the pressure regulator, bleed the air line to clear it of accumulated dirt or water before connecting the air hose to the
tool. If there is a filter, drain it.
•
Check that the nose assembly is correct for the fastener to be placed.
•
Ensure Deflector
47
is fitted to the tool.
•
Check the stroke of the tool meets the minimum specification (page 5). The last steps of the Priming Procedures on pages 19 and 20 explain
how to measure the stroke.
•
Check that the anvil is not worn. This can be confirmed by referring to the installed data on the fastener datasheet. Excessive wear can
cause the anvil to rupture.
Weekly
1
Dismantle and clean the nose assembly with special attention to the jaws. Lubricate with MolyLithium grease before assembling.
1
Check for oil leaks and air leaks in the air supply hose and fittings.
MolyLithium Grease EP 3753 Safety Data
Grease can be ordered as a single item, the part number is shown in the Service Kit page 12.
First Aid
SKIN:
As the grease is completely water resistant it is best removed with an approved emulsifying skin cleaner.
INGESTION:
Ensure the individual drinks 30ml Milk of Magnesia, preferably in a cup of milk.
EYES:
Irritant but not harmful. Irrigate with water and seek medical attention.
Fire
FLASH POINT: Above 220°C.
Not classified as flammable.
Suitable extinguishing media: CO2, Halon or water spray if applied by an experienced operator.
Environment
Scrape up for incineration or disposal on approved site.
Handling
Use barrier cream or oil resistant gloves.
Storage
Away from heat and oxidising agent.
Item numbers in
bold