9
Collar Splitter, Adaptor Kit (73200-04600)
Installation instructions
Body Disassembly
•
To fit these collar splitters, disconnect tool from air supply
•
Remove pin tail deflector
47
.
•
Remove nose assembly, if fitted
•
Lubricate the collar splitter cam faces, bearing faces and any moving parts with
Moly Lithium Grease.
•
Holding the head piston with a 10mm A/F” Allen Key through he back of the
tool, tighten the collet adaptor onto the head piston with a spanner.
•
Push the anvil adaptor over the collet adaptor and screw on. Tighten with a
spanner
•
Insert the assembled collar splitter into the anvil adaptor and screw onto the
end of the collet adaptor. Tighten the nose retaining nut on the anvil adaptor
with a spanner
•
To operate, push the collar splitter hard over the collar and depress the trigger.
•
To cut 5/16” or 3/8” Avdelok® use 07220-03700 and 07220-03900 collar splitters
respectively – no adaptor kit is required.
•
Fit Head Vice Jaw* to Head
63
and use soft jaws to hold the Head Vice Jaw in
the inverted orientation.
•
Use Locknut Socket* to unscrew Locknut
38
. If necessary, use a 10mm A/F
Allen key to prevent rotation of Base Plate
32
.
•
Remove Base Cap
31
and Gasket
36
.
•
Remove Retaining Ring
25
and Silencer
37
.
•
Push Base Plate
32
into Body
65
and remove Retaining Ring
24
.
•
With Base Plate extractor* fitted to underside of Body
65
, screw Locknut
38
onto Base Plate
32
, extracting Base Plate from Body. If
necessary, use a 10mm A/F Allen key to prevent rotation of Base Plate.
•
Screw Piston Stop to underside of Air Piston
33
locate using M6 screws into base and screw on.
* Contained in Service Kit
It is necessary to remove these accessories for priming of the tool.