background image

User manual

 

Drive unit DAE-01 CL

10

5.  Configuration menu

The  Configuration  menu  allows  the  individually  adaptation  of  the  drive 
unit to the requirements of the platter. 

For the correct speed, the relationship between the pulley and the platter 
must  be  considered  very  carefully.  It  is  also  very  important  to  optimize 
acceleration and braking forces in order to match the material properties 
of the drive belt and the mass of the platter.
This allows the drive unit to be optimally adjusted to the pairing with the 
platter and adapted to actual conditions.

The channels are not numbered consecutively, they are organized in mea-
ningful categories:

•   Channels below 100 are intended for the general channels „Dimmer“, 
 

„Key Delay“ and „Pickup“.

•   Channels 100 ... 123 concern the „Set“
•   Channel 999 is for reset to factory defaults 

„Gaps“  in  channel  numbering  during  selection  therefore  are  completely 
normal.

5.1 

Call up Configuration menu

► 

Press and hold the [On Off] key and then briefly press the [-] key to 

 

enter the Configuration menu.

The display changes to the channel display („c“ and channel number):

Function

Display

Configuration menu

                     +

        

 

► 

Press [On Off] to exit the Configuration menu.

5.2 

Channel selection

► 

Press [+] to increase channel number.

► 

Press [-] to decrease channel number.

After selecting the channel to be edited, the channel number and the cur-
rent value for this channel are displayed alternately.

channel value

channel number

5.3 

Changing channel value

► 

Press and hold the [33 45] key and then briefly press the [+] key to 

 

increase channel value.

► 

Press and hold the [33 45] key and then briefly press the [-] key to 

 

decrease channel value.

Pressing and holding the buttons [+] [-] for a longer time will change the 
channel  value  continuously,  whereby  the  step  size  of  the  change  of  the 
channel value increases by the duration of the button operation.

► 

Press and hold the [33 45] and [On Off] key to restore the original 

 

channel value („Undo“).

While the channel value is changed, only the channel value is shown in the 
display.

The effect of change a channel value is immediate, if possible. For exam-
ple, the speed settings are directly passed on to the motor with each chan-
nel value change, so that the resulting changes can be checked directly.

If the value of a channel is not changed for a certain time, the current value 
for this channel and the channel number is displayed alternately again.

When  you  exit  the  Configuration  menu  by  pressing  the  [On Off]  key,  
changed channel values are stored in the non-volatile memory and thus 
remain safely stored until any later changes are made, even in the event 
of a power failure.

Some channels are used only to display actual values. 
A change of these channel values therefore is not possible.

 

There is no need to hurry while changing values in the Con-
figuration menu. 
The Configuration menu will not be exited until the [On Off] 
key has been pressed.

Summary of Contents for Dereneville DAE-01 CL

Page 1: ...User manual Drive unit DAE 01 CL DAE 01 CL Dereneville High End a decision for a lifetime ...

Page 2: ...oftware design combines highest precision flexibility and intuitive operation Essential components of our design are Powerful 16 bit microcontroller by Fujitsu High precision embedded real time operating system Software designed programmed and tested according to automotive standards Sophisticated interrupt system ensures the synchronization of the software Papst BLDC Motor Now we are particularly...

Page 3: ...f the drive unit Off 8 4 4 Activating Motion Care function 8 4 5 Starting stopping the motor 8 4 6 Select speed 8 4 7 Vary standard speed Pitch 9 4 8 Operating time alerts 9 5 Configuration menu 10 5 1 Call up Configuration menu 10 5 2 Channel selection 10 5 3 Changing channel value 10 5 4 General configuration channels 11 5 4 1 Dimmer 11 5 4 2 Key Delay 11 5 5 Overview set channels 12 5 5 1 Speed...

Page 4: ...ed by the adjacent symbol These informations are limited by lines above and below the text 1 2 Important information Symbol Meaning Instruction for action Reference to a text passage in the document Enumeration List entry Enumeration List entry 2nd level 1 3 Environmental protection Packaging disposal The packaging protects the device from transport damage The packaging materials have been selecte...

Page 5: ...ins plug the mains cable the mains adapter or the appliance itself WARNING Repairs only by the manufacturer 2 Safety Instructions Read these operating instructions carefully and completely before attempting to install and operate the device Keep these operating instructions in a safe place This manual contains important safety and operating instructions for the use of the drive unit If the device ...

Page 6: ... 1 The motor runs When the motor runs the corresponding speed of the platter is displayed If a speed deviating from the standard value has been selected Pitch the display shows the actual speed If the motor accelerates or brakes the target speed display flashes to indicate that the target speed has not yet been achieved The characteristics of this dynamic can be configured which means that the dur...

Page 7: ...es the platter at a reduced speed for about 20 s Once the set rotation time has elapsed the motor stops and the drive unit starts to countdown the waiting time until the next run of Motion Care When the Motion Care function is activated the current status of the func tion is shown on the display Display MotionCare Status The remaining time until the next MotionCare run is displayed in hh mm If the...

Page 8: ...g the On Off key for more than 6 s the drive unit changes from operating mode On respectively from the standby mode Off to activated Motion Care function Modus Display MotionCare function more than 6 s 4 5 Starting stopping the motor To start the motor press key 33 45 to select the last used platter speed As long the motor accelerates or brakes the target speed display flashes to indicate that the...

Page 9: ... dynamic phase and the selected speed has not yet been achieved A pitch setting will not be stored A varied speed setting is retained only until key 33 45 is pressed again or the device is switched off with key On Off 4 8 Operating time alerts In order to ensure optimum playback quality and to protect your valuable vinyl discs the drive belt and pickup should be replaced after a certain period of ...

Page 10: ...r rent value for this channel are displayed alternately channel value channel number 5 3 Changing channel value Press and hold the 33 45 key and then briefly press the key to increase channel value Press and hold the 33 45 key and then briefly press the key to decrease channel value Pressing and holding the buttons for a longer time will change the channel value continuously whereby the step size ...

Page 11: ... 121 Timer Drive belt actual no Time 122 Timer Pickup target yes 0 9999 123 Timer Pickup actual no Time We recommend the following standard settings Gain Channel 110 value 150 Acceleration Channel 111 value 400 Brake Channel 112 value 100 With these settings the time for acceleration is approx 5 s and the time for deceleration also approx 5 s 5 5 1 Speed adjustment The speed adjustment should be d...

Page 12: ...ration 5 5 3 Gain Gain describes the non linear behaviour of 1st order during acceleration or deceleration The set value describes the gradient of the drive characte ristic curve with which the nominal speed is achieved Channel Function Variable Range of values 110 Gain yes 1 200 The higher this value is set the steeper the drive characteristic curve is and the faster the nominal speed is achieved...

Page 13: ...ectronics no Days 5 5 7 Reset Channel 999 resets the operating parameters Set to the factory set tings This means the speeds are set for a 30 cm platter the operating hour counters for pickup and drive belt and their maxi mum operating hours are reseted The recorded operating hours for motor and drive unit are not affected by the reset Channel Function Display 999 Reset to factory settings To perf...

Page 14: ...ortati on nor any other costs or risk for removal transport and installation of the products is covered by the warranty 2 The warranty is transferable 3 The warranty is not valid for damage caused by incorrect installation connection or packaging for damage caused by use negligence or use of parts other than those described in the user manual or use of parts not manufactured or authorized by AVDes...

Page 15: ... manual Drive unit DAE 01 CL 15 9 Dimensions DAE 01 CL 8 14 6 93 87 73 5 100 24 VDC only for Service H 10 D 14 ideale Riemenbreite 6 mm Rundriemen String 2 5 mm 118 Ideal belt width 6 mm Round belt Ø 2 5 mm ...

Page 16: ...Dereneville High End a decision for a lifetime ...

Reviews: