background image

- 37 -

G

Function 4: GSM network search time programming (15 or 30 seconds).
Jumper JP1 must be inserted in the INST position during this programming.

FUNZIONI

FUNZIONI

Programming of FUNCTIONS

Choose the search time by using keys (

)

and (#): 15 or 30 seconds

FUNCTION 4 entering: network search time
programming

T   Attesa

T   Attesa

15  sec

15  sec

4

Confirmation of programming through

and exit from the function by

or time-out 

Note 4: The network research time by the portable telephone must be programmed only after

checking the actual research time in the installation environment.

*

#

C.415  10-06-2002  9:11  Pagina 37

Summary of Contents for AF902R-CE

Page 1: ...Combinatore Telefonico Cellulare con comando radio Mobile GSM Telephone Dialler with radio control COD AF902R CE C415 00 170300 C 415 10 06 2002 9 11 Pagina 2...

Page 2: ...I Combinatore Telefonico Cellulare con comando radio COD AF902R CE I C 415 10 06 2002 9 11 Pagina 3...

Page 3: ...deve essere maneggiato con cura e immagazzinato in luogo asciutto ad una temperatura compresa tra 5 e 40 C Si ricorda inoltre Togliere tensione agendo sull interruttore generale prima di operare sull...

Page 4: ...a nominale del collegamento 30 metri in condizioni normali nell ambiente abitativo pareti metalliche o strutture antisismiche possono ridurre la portata Codice utente da 4 a 7 cifre 2 canali di trasmi...

Page 5: ...l segnale di blocco chiama il secondo numero memorizza to e cos via fino al quarto numero Prima di passare alla chiamata del numero successivo il combinatore attende che siano stati emessi 8 squilli 4...

Page 6: ...del combinatore hanno le seguenti funzioni TASTO FUNZIONE Programmazione numeri telefonici e digitazione codici numerici Programmazioni speciali Programmazioni speciali Selezione della programmazione...

Page 7: ...dizione di tensione batteria SOGLIA 1 viene segnalata dall LCD tramite la seguente scritta per tutto il tempo in cui presente la condizione Nota 1 la condizione di tensione batteria SOGLIA 1 pu anche...

Page 8: ...ICE di FABBRICA e successivamente tramite il CODICE UTENTE impostato L uscita dalla programmazione avviene automaticamente dopo 16 s dalla digitazione dell ulti mo tasto uscita per TIME OUT oppure pre...

Page 9: ...lativi al canale 2 NUMERO 1 NUMERO 1 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 1 Conferma del numero programmato con ed uscita dalla programmazione per o time out A Prima programmazione Programmazione NUMERI Co...

Page 10: ...a programmazione NUMERO 1 Per modificare i numeri di telefono successivi sufficiente impostare il relativo numero progressivo da 2 a 8 I numeri 1 2 3 4 sono relativi al canale 1 i numeri 5 6 7 8 sono...

Page 11: ...e modifica MESSAGGIO 1 Funzione 2 registrazione ascolto e modifica MESSAGGIO 2 Funzione 3 impostazione visualizzazione e variazione CODICE UTENTE Funzione 4 programmazione del tempo di ricerca rete 15...

Page 12: ...0 FUNZIONI FUNZIONI Programmazione FUNZIONI Registrazione MESSAGGIO 1 tenere premuto il tasto per tutta la durata della registrazione tt indica il conto alla rovescia in secondi Accesso alla FUNZIONE...

Page 13: ...dopo la registrazione MESSAG MESSAG 1 1 REGis REGis tt tt PLAY 1 PLAY 1 1 Modifica MESSAGGIO 1 Ascolto MESSAGGIO 1 gi registrato Conferma MESSAGGIO 1 gi registrato oppure modifica tramite REGistR 1 R...

Page 14: ...00 e di modificare quindi il codice precedentemente pro grammato Attenzione Se questa operazione non eseguita entro 30 s il combinatore ritorna nella condizione in cui accetta solo il codice utente pr...

Page 15: ...ramite i tasti e il tempo di ricerca 15 o 30 secondi Accesso alla FUNZIONE 4 programmazione del tempo di ricerca rete T Attesa T Attesa 15 sec 15 sec 4 Conferma della programmazione con ed uscita dall...

Page 16: ...sito POSITIVO segnalazione presente per 4 s Digitare il numero telefonico a cui inviare il messaggio per il TEST MESSag 1 MESSag 1 TEST OK TEST OK _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ TEST TEL TEST TEL Fun...

Page 17: ...eri 3 e 4 con invio di tonalit acustica al posto del messaggio vocale Il ponticello JP1 deve essere in posizione INST per accedere a questa funzione Nota 5 Per attivare questa funzione scegliere Y pre...

Page 18: ...o I codici 1 2 3 4 attivano il canale 1 mentre i codici 5 6 7 8 attivano il canale 2 Il ponticello JP1 deve essere in posizione INST per accedere a questa funzione A Prima memorizzazione di codice rad...

Page 19: ...e il combinatore entro 30 s agendo sul tasto verde Telecomando AF938R Premere entrambi i tasti del telecomando per circa 5 s In queste condizioni il telecomando trasmette il proprio codice che viene m...

Page 20: ...odice radio gi stato programmato Accesso alla variazione CODICE 1 Eseguire la modalit di programmazione del dispositivo trasmittente interessato Vedi Nota 6 Se in questa combinazione non viene memoriz...

Page 21: ...ogrammazione di CODICE 5 CODICE 8 COD mes 2 COD mes 2 8 5 Accesso alla programmazione CODICE 5 Per effettuare la programmazione dei codici successivi sufficiente impostare il relativo numero progressi...

Page 22: ...ene memorizzato alcun codice si ha la cancellazione del codice precedentemente memorizzato con emissione di 2 beep Conferma dell avvenuta variazione di CODICE 5 con riscontro acustico musicale 3 s se...

Page 23: ...a questa funzione Nota 7 Per attivare questa funzione scegliere Y premendo il tasto Per disattivare questa funzione scegliere N premendo il tasto 22 I FUNZIONI FUNZIONI Programmazione FUNZIONI Progra...

Page 24: ...i comando Allarme manomissione Il contenitore prevede un contatto NC 50mA 60Vcc TAMPER contro l apertura dell involu cro e contro l asportazione Il segnale di allarme manomissione non viene trasmesso...

Page 25: ...telecomando AF902R CE 1 F 2 3 4 5 6 7 8 9 0 RIV IRP RADIO AF968R RIVELATORE PERIMETRALE MULTIFUNZIONE AF913R AF913R M TELECOMANDO AF939R 2 Comando combinatore da centrale antifurto CENTRALE ANTIFURTO...

Page 26: ...24 G Mobile GSM Telephone Dialler with radio control COD AF902R CE G C 415 10 06 2002 9 11 Pagina 24...

Page 27: ...the user After opening the packing check the product s ntegrity in case of doubt do not use the equipment and con sult skilled personnel Even when wrapped in its packing the equipment must be handled...

Page 28: ...5 8 V Connection rated range 30 meters under standard conditions in domestic environments metal walls or aseismatic structures may reduce the range User code from 4 to 7 figures 2 independent transmit...

Page 29: ...ceiving the alarm call If the dialler does not receive the block signal it calls the second stored number and so on up to the fourth number Before calling the next number the dialler awaits that 8 rin...

Page 30: ...keys The dialler keys have the following functions KEY FUNCTION Telephone number programming and numeric code dialling Special programming Special programming NUMBER programming selection FUNCTION pr...

Page 31: ...on of battery voltage threshold 1 is displayed by the following warning during all the time the condition persists Note 1 the condition of battery voltage threshold 1 can also enable the operating cyc...

Page 32: ...ramming To enter the programming for the first time use the FACTORY CODE Then use the pre set USER CODE The programming exit is made automatically after 60 seconds after pressing the latest key TIME O...

Page 33: ...1 G NUMERI NUMERI Programming of NUMBERS Keystroke NUMBER 1 16 figures MAX Entering of programming NUMBER 1 To program the next telephone numbers just set the related progressive number from 2 to 8 Nu...

Page 34: ...g of programming NUMBER 1 To change the next telephone numbers just set the related progressive number from 2 to 8 Numbers 1 2 3 4 are related to channel 1 whereas numbers 5 6 7 8 are related to chann...

Page 35: ...d change of MESSAGE 1 Function 2 recording listening and change of MESSAGE 2 Function 3 setting display and change of USER CODE Function 4 network search time programming 15 or 30 seconds Function 5 G...

Page 36: ...directly entered FUNZIONI FUNZIONI Programming of FUNCTIONS Recording of MESSAGE 1 keep the key pressed during the whole recording step tt stands for the countdown expressed in seconds FUNCTION 1 ent...

Page 37: ...number Listening to the modified MESSAGE 1 in automatic sequence after recording MESSAG MESSAG 1 1 REGis REGis tt tt PLAY 1 PLAY 1 1 Change of MESSAGE 1 listening to MESSAGE 1 already recorded confir...

Page 38: ...amming with the factory code 0000 within a period of 30 s and to modify the previously programmed code Warning If this operation is not performed within 30 sec the dialler returns to the condition in...

Page 39: ...search time by using keys and 15 or 30 seconds FUNCTION 4 entering network search time programming T Attesa T Attesa 15 sec 15 sec 4 Confirmation of programming through and exit from the function by o...

Page 40: ...ne TEST is positive indication on for 4 seconds Keystroke the telephone number the TEST message must be sent to MESSag 1 MESSag 1 TEST OK TEST OK _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ TEST TEL TEST TEL Func...

Page 41: ...numbers 3 and 4 by means of sound tones instead of voice announcements The JP1 jumper must be on the INST position to enter this function Note 5 to enable this function choose Y by pressing key to di...

Page 42: ...channel also of different types Codes 1 2 3 4 enable channel 1 whereas codes 5 6 7 8 enable channel 2 Jumper JP1 must be on the INST position to enter this function A First storing of the radio code...

Page 43: ...allows to stop the dialler within 30 seconds through the green key AF938R remote control Press both the keys of the remote control for 5 seconds approx Under this condition the remote control transmi...

Page 44: ...s that the radio code has already been programmed CODE 1 modification entering Execute the programming mode of the invol ved transmitting device see note 6 If no code is stored through this combina ti...

Page 45: ...UNCTION 8 entering Programming of CODE 5 CODE 8 COD mes 2 COD mes 2 8 5 CODE 5 programming entering To perform the programming of next codes just set the related progressive number Execute the program...

Page 46: ...is stored through this combina tion the code previously stored will be can celled after emitting 2 beeps Confirmation of modification of CODE 5 with sound confirmation 3 sec if it is OK if not 2 beep...

Page 47: ...function Note 7 To enable this function choose Y by pressing key To disable this function choose N by pressing key FUNZIONI FUNZIONI Programming of FUNCTIONS Programming of the keypad block see note...

Page 48: ...connector Tamper alarm The enclosure is provided with a NC 50 mA 60Vdc contact TAMPER against the opening of the envelope and its removal The tamper alarm signal is not transmitted to the control pane...

Page 49: ...e control AF902R CE 1 F 2 3 4 5 6 7 8 9 0 RADIO PIR DETECTOR AF968R MULTI FUNCTION DOOR WINDOW DETECTOR AF913R AF913R M REMOTE AF939R 2 Dialler control from a burglar control panel RADIO BURGLAR CONTR...