- 13 -
Code reset
This procedure allows to delete the
master, keypad and user codes
previously
stored.
1)
Open the keypad enclosure.
2)
Press the internal reset pushbutton for 3s; a beep is heard and any led ON will
switch OFF.
Connection, Disconnection, partial setting
Connection, disconnection and partial setting can be carried out according to the
instructions below, through the keypad, after setting the keypad code and the user
code, exiting from the programming mode and setting the control unit key to ON posi-
tion.
“Anti-scanner” protection
If the user code or the master code do not correspond to the stored ones, after the third
attempt, the keypad will set to stand-by for 30s; the yellow led will flash to signal this
status; during this time no further codes can be inserted.
Auxiliary signals
The keypad supplies important information on the status of the system such as ano-
maly and alarm warning signals. These warning signals are recapitulatory and make
the user control the pilot lamps of the control unit to check the events occurred in
detail. The table below shows the way this information is signalled along with its mea-
ning.
Insert the 4-figure user code previously stored: the three
leds seated on the keypad will start flashing. Press the red
key: all the zone LEDs (A, B, C) will switch ON; after 1 minu-
te, only the green led signalling the “system connected” sta-
tus will remain ON.
Insert the 4-figure user code previously stored: the three
leds seated on the keypad will start flashing. Press the green
led: in the control unit, the LEDs of the channels that have
stored alarms, will start flashing.
Zones A – B – C can be enabled individually as follows.
Insert the 4-figure user code previously stored (the three
leds seated on the keypad will start flashing).
Then, press the keys of the zones to be excluded (A, B, C).
(the three leds seated on the keypad related to the zones will
confirm the set command: LED ON = zone enabled). Make
sure that setting is the desired one and press the red key.
The LEDs related to the zones enabled will remain ON for 1
minute. Once this time is over, only the green led will switch
ON or remain ON to signal the “connected system” status
without detecting the partial setting, if any.
The preset partial setting remains stored up to the next dis-
connection of the system.
FULL
CONNECTION
DISCONNECTION
PARTIAL
SETTING