security (for ex. Intrusion alarm systems, etc.) the power supply of the
device must be connected to a buffer power supply system so that, in the
event of long mains failure, the decoder performance is not jeopardized.
Deletion of codes stored in the decoder
All previously stored codes can be deleted by pressing the reset pushbutton P1 for 3
seconds (fig. 3D). Moreover, by pressing pushbutton P1, the output relay will be de-
energized.
DECODER TERMINAL BOARD DESCRIPTION
TECHNICAL DATA OF DECODER 45378DF
• Rated voltage: 12Vdc/ac
• Permitted change: 10 to 15Vdc or at 12Vac (-20%, +30%max)
• Max. consumption: 25mA with excited relay, led ON and code transmission in pro-
gress
• Inputs: 2 terminals each key reader serial input (AF45341)
• Outputs: 3 terminals each changeover potential-free contact 1A/30V NO+NC
• Status signalling LEDs
• Maximum number of storable codes: 8
• P1 pushbutton: to delete all codes acknowledged
• J1 jumper: to select the operating mode (monostable or bistable)
• J2 jumper: to enter the programming mode
• Installation: indoor, wall or flush-mounting in the special enclosure
• Dimensions: 1 S45 module.
- 16 -
Terminals
Description
Jumper
1
Power supply negative
2
Power supply positive
3
Serial input
4
NO contact
5
Common contact
6
NC contact
J1
To select the operating mode of the output (monostable or bistable)
J2
To move from the programming mode to the operating mode
P1
To delete the stored codes
C421 14-10-2005 14:50 Pagina 16