background image

Page 9 

NOTICE TO PRODUCT USERS

 

1. WARNING: FLUID MEDIA

AVENTICS pneumatic devices are designed and tested for use
with  filtered,  clean,  dry,  chemical  free  air  at  pressures  and
temperatures  within  the  specified  limits  of  the  device.  For  use
with  media  other  than  air  or  for  human  life  support  systems,
AVENTICS must be consulted. Hydraulic cylinders are designed
for operation with filtered, clean, petroleum based hydraulic fluid;
operation using fire-resistant or other special types of fluids may
require special packing and seals. Consult the factory.

2. WARNING: MATERIAL COMPATIBILITY

Damage  to  product  seals  or  other  parts  caused  by  the  use  of
noncompatible  lubricants,  oil  additives  or synthetic lubricants  in
the  air  system  compressor  or  line  lubrication  devices  voids
AVENTICS  warranty  and  can  result  in  product  failure  or  other
malfunction. See lubrication recommendations below.

AIR  LINE  LUBRICANTS! 

In service higher than 18 cycles per

minute  or  with  continuous flow  of  air  through the  device,  an  air
line lubricator is recommended.* (Do not use line lubrication with
vacuum  products.)  However,  the  lubricator  must  be  maintained
since the oil will wash out the grease, and lack of lubrication will
greatly  shorten  the  life  expectancy.  The  oils  used  in  the
lubricator must be compatible with the elastomers in the device.
The  elastomers  are  normally  BUNA-N,  NEOPRENE,  VITON,
SILICONE  and  HYTREL.    AVENTICS  recommends  the  use  of
only  petroleum  based  oils  without  synthetic  additives,  and  with
an aniline point between 180° F and 210° F.

COMPRESSOR  LUBRICANTS! 

All  compressors  (with  the

exception of special "oil free" units) pass oil mist or vapor from
the  internal  crankcase  lubricating  system  through  to  the
compressed  air.  Since  even  small  amounts  of  non-compatible
lubricants  can  cause  severe  seal  deterioration  (which  could
result  in  component  and system  failure)  special care should  be
taken in selecting compatible compressor lubricants.

3. WARNING: INSTALLATION AND MOUNTING

The  user  of  these  devices  must  conform  to  all  applicable
electrical, mechanical, piping and other codes in the installation,
operation or repair of these devices.

INSTALLATION  ! 

Do  not  attempt  to  install,  operate  or  repair 

these devices without proper training in the technique of working 
on  pneumatic  or  hydraulic  systems  and  devices,  unless  under 
trained  supervision.    Compressed  air  and  hydraulic  systems 
contain high levels of stored energy. Do not attempt to connect, 

disconnect  or  repair  these  products  when  a  system  is  under 
pressure.  Always  exhaust  or  drain  the  pressure  from  a  system 
before performing any service work.  Failure to do so can result 
in serious personal injury. 

MOUNTING! 

Devices should be mounted and positioned in such 

a manner that they cannot be accidentally operated. 

4. WARNING: APPLICATION AND USE OF PRODUCTS

The  possibility  does  exist for  any  device  or  accessory  to fail to
operate properly through misuse, wear or malfunction. The user
must consider these possibilities and should provide appropriate
safe  guards  in  the  application  or  system  design  to  prevent
personal injury or property damage in the event of a malfunction.

5. WARNING: CONVERSION, MAINTENANCE AND REPAIR

When  a  device  is  disassembled  for  conversion  to  a  different
configuration, maintenance or repair, the device must be tested
for  leakage  and  proper  operation  after  being  reassembled  and
prior to installation.

MAINTENANCE  AND REPAIR! 

Maintenance periods should be

scheduled  in  accordance  with  frequency  of  use  and  working
conditions. All AVENTICS products should provide a minimum of
1,000,000  cycles  of  maintenance  free  service  when  used  and
lubricated as recommended. However, these products should be
visually inspected for defects and given an "in system" operating
performance  and  leakage  test  once  a  year.  Where  devices
require a major repair as a result of the one million cycles, one
year,  or  routine  inspection,  the  device  must  be  disassembled,
cleaned,  inspected,  parts  replaced  as  required,  rebuilt  and
tested for leakage and proper operation prior to installation. See
individual catalogs for specific cycle life estimates.

6. PRODUCT CHANGES

Product changes including specifications, features, designs and
availability are subject to change at any time without notice. For
critical dimensions or specifications, contact factory.
*Many  AVENTICS  pneumatic  valves  and  cylinders  can  operate
with  or  without  air  line lubrication; see  individual sales catalogs
for details.

LIMITATIONS OF WARRANTIES & REMEDIES

 

AVENTICS warrants its products sold by it to be free from defects in material and workmanship to the following: 
For  twelve  months  after  shipment  AVENTICS  will  repair  or  replace  (F.O.B.  our  works),  at  its  option,  any  equipment  which  under 
normal conditions of use and service proves to be defective in material or workmanship at no charge to the purchaser.  No charge will 
be  made  for  labor  with  respect  to  defects  covered  by  this  Warranty,  provided  that  the  work  is  done  by  AVENTICS  or  any  of  its 
authorized  service  facilities.    However,  this  Warranty  does  not  cover  expenses  incurred  in  the  removal  and  reinstallation  of  any 
product, nor any downtime incurred, whether or not proved defective. 
All  repairs  and  replacement  parts  provided  under  this  Warranty  policy  will  assume  the  identity,  for  warranty  purposes,  of  the  part 
replaced, and the warranty on such replacement parts will expire when the warranty on the original part would have expired.   Claims 
must be submitted within thirty days of the failure or be subject to rejection. 
This Warranty is not transferable beyond the first using purchaser.  Specifically, excluded from this Warranty are failures caused by 
misuse, neglect, abuse, improper operation or filtration, extreme temperatures, or unauthorized service or parts.  This Warranty also 
excludes the use of lubricants, fluids or air line additives that are not compatible with seals or diaphragms used in the products.  This 
Warranty  sets  out  the  purchaser's  exclusive  remedies  with  respect  to  products  covered  by  it,  whether  for  negligence  or  otherwise.  
Neither, AVENTICS nor any of its affiliates will be liable for consequential or incidental damages or other losses or expenses incurred 
by reason of the use or sale of such products.  Our liability (except as to title) arising out of the sale, use or operation of any product or 
parts,  whether  on  warranty,  contract  or  negligence  (including claims  for  consequential  or  incidental damage)  shall  not  in  any  event 
exceed the cost of replacing the defective products and, upon expiration of the warranted period as herein provided, all such liability is 
terminated.    THIS  WARRANTY  IS  IN  LIEU  OF  ALL  OTHER  WARRANTIES,  EXPRESS  OR  IMPLIED,  WHETHER  FOR 
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE.  No attempt to alter, amend or extend this 
Warranty shall be effective unless authorized in writing by an officer of AVENTICS Corporation. 
AVENTICS reserves the right to discontinue manufacture of any product, or change product materials, design or specifications without 
notice.

 

Summary of Contents for AA-1

Page 1: ...diaphragm that is controlled by a separate valve H 4 CONTROLAIR Valve AB 1 Basic AA Type positioner with a separately controlled stop cylinder INSTALLATION Mount the positioner firmly to the engine fr...

Page 2: ...d old vernier follower ref 20 pg 6 will function with the new or old lever arm the old stop cylinder will function with the new lever arm provided the old connecting link ref 18 pg 7 is used and the n...

Page 3: ...00000 2 1 BOLT 1 4 20 x 2 3 4 Hex P 049900 00012 P 049900 00005 3 8 WASHER Spring P 050232 00000 4 2 RACE Inner Bearing P 050175 00000 P 050175 00001 5 2 BEARING Needle 537898 6 1 COTTER 3 32 x 5 8 9...

Page 4: ...y R431005429 P 060257 00000 6 1 SPRING R431000016 520964 00000 7A 2 SHIM 010 Spring R431005425 P 060255 00000 See note 3 7B 1 SHIM 031 Spring R431005426 P 060255 00002 See note 3 7C 1 SHIM 125 Spring...

Page 5: ...000058 11 2 BEARING Nylon See Repair Kit See note 1 2 See Repair Kit 12 1 SPACER P 060260 00000 See note 2 R431005432 13 1 ARM Lever P 060274 00001 See note 2 R431005452 14 1 BAR Adapter P 027984 0000...

Page 6: ...060274 00000 See note 2 R431005451 14A 1 ROD Operator 1 4 Rod Eye P 050564 00003 R431002665 14B 1 ROD Operator 5 16 Rod Eye P 050564 00004 R431002666 14C 1 ROD Operator 3 8 Rod Eye P 050564 00002 R43...

Page 7: ...7 2 BEARING Nylon 11 1 SEAL U Cup 27 1 O RING 29 Not shown here refer to pg 4 ref 4 AB 1 OPERATOR REPAIR KIT REF QTY DESCRIPTION OLD P N NOTES NEW P N 1 3 NUT 1 4 20 P 049891 00000 R431002406 2 3 BOL...

Page 8: ...Page 8...

Page 9: ...enance periods should be scheduled in accordance with frequency of use and working conditions All AVENTICS products should provide a minimum of 1 000 000 cycles of maintenance free service when used a...

Page 10: ...T 0 r tario CMIAML7r t TM w w t I a 1te r1tic sc cam ca ir1Fa c a a eJTtic s com Slv1 9QQ 44Q1 May 2QT4 Sub1ec ttn c hange Printed in Unite ct States AVENTICS Carparatian This dac urnent as well as th...

Reviews: