SERVICE INFORMATION 

 

WARNING: INSTALLATION AND 

 MOUNTING 

 

 
 
The user of these devices must conform to all applicable 
electrical, mechanical, piping and other codes in the 
installation, operation or repair of these devices. 
 

INSTALLATION!

 Do not attempt to install, operate or 

repair these devices without proper training in the 
technique of working on pneumatic or hydraulic systems 
and devices, unless under trained supervision. 
Compressed air and hydraulic systems contain high 
levels of stored energy. Do not attempt to connect, 
disconnect or repair these products when a system is 
under pressure. Always exhaust or drain the pressure 
from a system before performing any service work. 
Failure to do so can result in serious personal injury. 
 

MOUNTING!

 Devices should be mounted and 

positioned in such a manner that they cannot be 
accidentally operated. 

  
 

INSTALLATION 

 

Before

 

installing

 

this

 

cylinder,

 

all

 

air

 

lines

 

in

 

the

 

system

 

should

 

be

 

blown

 

clean

 

to

 

remove

 

any

 

moisture

 

or

 

loose

 

material.

 

Also,

 

the

 

area

 

in

 

which

 

the

 

cylinder

 

is

 

to

 

be

 

mounted

 

should

 

be

 

free

 

of

 

any

 

foreign

 

objects,

 

which

 

may

 

damage

 

the

 

cylinder

 

barrel.

 

To

 

further

 

ensure

 

a

 

long,

 

trouble

free

 

service,

 

an

 

e

cient

 

air

 

fi

lter

 

should

 

be

 

installed

 

in

 

the

 

system’s

 

supply

 

line.

  

 
 

Start

 

the

 

installa on

 

by

 

removing

 

one

 

co er

 

pin

 

and

 

clevis

 

pin

 

from

 

the

 

clevis

 

on

 

the

 

cap

 

end

 

of

 

the

 

cylinder.

 

Set

 

the

 

cylinder

 

into

 

the

 

moun ng

 

posi on

 

with

 

the

 

cap

 

clevis

 

ma ng

 

with

 

the

 

moun ng

 

eye.

 

Reinstall

 

the

 

clevis

 

pin

 

through

 

the

 

clevis

 

lugs,

 

and

 

the

 

co er

 

pin

 

into

 

the

 

clevis

 

pin.

 

Spread

 

the

 

ends

 

of

 

each

 

co er

 

pin

 

so

 

that

 

they

 

will

 

not

 

fall

 

out.

 

You

 

can

 

now

 

connect

 

the

 

piston

 

rod

 

end

 

to

 

the

 

moun ng

 

bracket,

 

no ng

 

proper

 

alignment

 

to

 

eliminate

 

any

 

binding.

  

 
 

Remove

 

the

 

thread

 

protectors

 

from

 

each

 

pipe

 

port

 

in

 

the

 

head

 

and

 

cap;

 

connect

 

air

 

lines

 

from

 

the

 

direc onal

 

control

 

valve.

 

Use

 

pipe

 

dope

 

on

 

the

 

air

 

line

 

fi

ngs,

 

not

 

any

 

kind

 

of

 

tape.

 

Be

 

sure

 

no

 

foreign

 

ma er

 

enters

 

the

 

ports

 

or

 

air

 

lines

 

during

 

the

 

me

 

they

 

are

 

open.

 

 

If

 

the

 

cylinder

 

is

 

to

 

be

 

painted,

 

be

 

sure

 

that

 

the

 

piston

 

rod

 

is

 

covered,

 

the

 

ports

 

are

 

closed,

 

and

 

the

 

clevis

 

pin

 

is

 

covered

 

where

 

it

 

rides

 

in

 

the

 

clevis.

 

 

The

 

supply

 

air

 

and

 

atmospheric

 

(ambient)

 

condi on

 

must

 

be

 

maintained

 

within

 

a

 

temperature

 

range

 

of

 

–40°F

 

to

 

+225°

F.

 

 
OPERATION  

 

When

 

the

 

cylinder

 

installa on

 

is

 

completed

 

correctly,

 

air

 

pressure

 

delivered

 

from

 

the

 

direc onal

 

valve

 

to

 

the

 

port

 

on

 

the

 

cap

 

end

 

of

 

the

 

cylinder

 

will

 

extend

 

the

 

piston

 

rod.

 

A

 

shi

 

of

 

the

 

valve

 

to

 

exhaust

 

that

 

air

 

and

 

to

 

apply

 

air

 

pressure

 

to

 

the

 

port

 

on

 

the

 

head

 

end

 

will

 

retract

 

the

 

piston

 

rod.

 

 
ADJUSTMENTS 