www.avenview.com
Page 9
INPUT PANEL (TRANSMITTER, HBT-C6POE-SP8) Rear
5.
HDMI IN: To receive the source INpuT
6.
HDMI OuT: Connect to HDMI display Max 35ft
via HDMI Cable or cascade with another Avenview
type Transmitter.
7.
CAT5e/6/7 OuT 1~7: Connect these ports to
CAT5e/6/7 HDMI Receivers (with or without poE func-
tion) with CAT5e/6/7 cable to extend the signal up to
60m/100m
8.
lAN: Connect to Internet service sharing rate of
100Mbps within the link of Transmitter. Warning:
DO NOT connect this port with any of the HDBa-
seT Receivers, this may trigger a power shot down
and damage device.
9.
IN: use IR Extender in this port.
10.
OuT: use IR Blaster in this port
11.
EDID: Configure Mode (see Details below *)
12.
SERVICE: This connector is reserved for factory
service only.
13.
DC 24V: To power the unit via the 24V DC power supply (supplied)
EDID TV: The default factory setting is TV; don’t adjust if the image is displayed properly.
EDID STD: Switch to STD to use built-in EDID if the image is not displayed properly.
STD EDID’s video at 1080p@60Hz and audio at lpCM 2CH.
5
6
8
7
9 10 11 12 13
The unit will detect the pORT (1) one CAT5e/6/7 output’s EDID. When it obtains a
(4Kx2K) ultra HD EDID the unit sends the signal accordingly to other (2) two output
ports. If pORT (1) one CAT5e/6/7 output is without a (4Kx2K) ultra HD EDID the unit
will detect all (7) output’s EDID and send the signal that all (7) outputs ports can accept.
This device obtains the last memory function. It will default use the last output pORT (1)
one EDID when output pORT (1) one is not connected to a display after power cycling
or switch in between the EDID setting.
Notice