The KPD-TCP1US-8, 8-Button Wall Plate Control Keypad has been tested for conformance to safety regulations and 
requirements, and has been certified for international use. However, like all electronic equipments, the HBT2-C6BPOC-SET 
should be used with care. Read the following safety instructions to protect yourself from possible injury and to minimize the 
risk of damage to the unit. 

Do not dismantle the housing or modify the module.
Dismantling the housing or modifying the module may result in electrical shock or burn.
Refer all servicing to qualified service personnel.
Do not attempt to service this product yourself as opening or removing housing may expose you to dangerous voltage
or other hazards.
Keep the device away from liquids.
Spillage onto the housing may result in fire, electrical shock, or equipment damage. If an object or liquid falls or spills on
to the housing, unplug the module immediately.
If the unit appears damagaed, have the module checked by a qualified service engineer before using it again.
Do not use liquid or aerosol cleaners to clean this unit. Always unplug the power to the device before cleaning.

!

!

!

!

!

!

!

!

1.1    

IMPORTANT SAFEGUARDS

• Any product on which the serial number has been defaced, modified or removed.
• Damage, deterioration or malfunction resulting from:
• Accident, misuse, neglect, fire, water, lightning, or other acts of nature, unauthorized product modification, or failure to 

   follow instructions supplied with the product.

• Repair or attempted repair by anyone not authorized by us.
• Any damage of the product due to shipment.
• Removal or installation of the product.
• Causes external to the product, such as electric power fluctuation or failure.
• Use of supplies or parts not meeting our specifications.
• Normal wear and tear.
• Any other causes which does not relate to a product defect.
• Removal, installation, and set-up service charges.

Please read all of these instructions carefully before you use the device. Save this manual for future reference.

Avenview warranty certificate please refer to page #20

Warranty does not include:

SECTION 1 

: GETTING STARTED

Rev.00 12/2017

www.avenview.com

1

Summary of Contents for KPD-TCP1US-8

Page 1: ...8 Button Wall Plate Control Keypad PRODUCT MANUAL Model KPD TCP1US 8 VIDEO WALLS VIDEO PROCESSORS VIDEO MATRIX SWITCHES EXTENDERS SPLITTERS WIRELESS CABLES ACCESSORIES Control Your Video...

Page 2: ...ecifications and product descriptions at any time without notice No license whether express implied or otherwise to any intellectual property rights is granted by this publication Except as set forth...

Page 3: ...6 3 INSTALLATION 7 3 1 TELNET CONFIGURATION 7 3 1 2 ENABLING TELNET CLIENT 8 3 2 LOGIN TO KPD TCP1US 8 VIA TELNET 9 3 3 TELNET COMMANDS 10 3 4 PC SOFTWARE 11 4 WEBGUI 12 4 1 CONFIGURATION SETTINGS 12...

Page 4: ...ave the module checked by a qualified service engineer before using it again Do not use liquid or aerosol cleaners to clean this unit Always unplug the power to the device before cleaning 1 1 IMPORTAN...

Page 5: ...ice pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipme...

Page 6: ...th system integrators and smart home users alike This keypad can send commands to any Ethernet or relay trigger controlled device in your system With up to 8 physical macro buttons and up to an additi...

Page 7: ...DC power adapter with correct specifications If inappropriate power supply is used then it may cause a fire Do not twist or pull by force ends of the UTP HDMI cable It can cause malfunction Keep the d...

Page 8: ...2 3 APPLICATION DIAGRAM Rev 00 12 2017 www avenview com 5...

Page 9: ...unit supports 48V PoE 3 DC 5V Plug in the 5V DC power adaptor included in the package and connect to AC wall outlet 3 2 1 2 4 2 I O PANEL KPD TCP1US 8 Rear 1 1 8 Macro Buttons Each button has a red an...

Page 10: ...ings of the unit is 192 168 1 50 subnet mask 255 255 225 0 Set your IP address in the 192 168 1 x range with a subnet mask of 255 255 255 0 To do this on a Windows PC follow the instructions below 3 1...

Page 11: ...om putty org By default the Telnet Client is disabled in Windows 7 Follow these instruction to enable the Telnet Client 1 Choose Start Control Panel Programs 2 In Programs and Features click Turn Wind...

Page 12: ...alog box enter cmd then click OK 3 Enter telnet 192 168 1 50 23 then press Enter 4 The Welcome Dialog will appear as below Enter API commands from this document to control and configure your KPD TCP1U...

Page 13: ...ess Sets the unit s netmask Sets the unit s gateway address Sets the unit s IP mode Returns the unit s firmware version Resets config settings to factory default Resets network settings to factory def...

Page 14: ...KPD TCP1US 8 to the same switch through another port You can also connect your computer to the keypad directly Ensure your PC is on the same subnet as the keypad See section 3 1 1 for more details an...

Page 15: ...tings of the Avenview KPD TCP1YS 8 8 Button Wall Plate Control Keypad can be configured through the WebGUI interface To access the WebGUI ensure your PC and the keypad are on the same network segment...

Page 16: ...button When you open the menu you will be presented with the current macro assigned to that button In the screenshot below you can see that this button has been configured to set the red LED backligh...

Page 17: ...on menu All commands may be configued with a delay interface and detination IP if applicable The image below shows the settings available for a Telnet command Delay The delay before the next command i...

Page 18: ...are required up to 32 commands between 128 and 512 characters can be saved with an additional 96 commands of 128 characters or less Commands should be entered as ASCII text or as hexadecimal character...

Page 19: ...Settings tab is used to change the behavior of buttons after they ve been pressed or held Each of the physical macro keys can be configured to in either Repeat or Toggle mode In Repeat mode when a key...

Page 20: ...a one time macro or a repeatedly scheduled macro click on the Edit button in either the Repeat or Once columns This will display the Macro Select menu 4 7 1 Macro Select Menu From the Macro Select men...

Page 21: ...e the WebGUI login and web connection timeout settings You can also download and restore the system configuration including macros to and from your PC Options to reboot and factory reset the unit are...

Page 22: ...LATIVE HUMIDTY KPD TCP1US 8 8 Button Wall Plate Control Keypad 8 x Buttons DC Power 1 x Relay Terminal Block 1 x RJ 45 Ethernet Port 5V 2 6A DC US EU standards CE FCC UL Certified 3 3W Human body mode...

Page 23: ...Rev 00 12 2017 www avenview com 20...

Page 24: ...tal or consequential damages in connection with the furnishing performance or use of the Avenview hardware software or other products and documentation provided herein Avenview Inc reserves the right...

Reviews: