Page|17
www.avenview.com
Loop Out provides the same unprocessed source signal from HDMI2.0-1 input port.
HDMI 2.0-2, DP and VGA ports input source signal can’t be looped out. It can only be selected
in the same EdgePro. If user wants to execute multi-unit edge blending through DP or VGA input
ports, please add DP or VGA video distributor and feed signal to all EdgePro.
User can connect any Loop Out signal to any HDMI input port in the next EdgePro. No specific
HDMI input port is assigned.
User can connect up to more than 10 units of EdgePro through daisy chain connection. The
daisy chain connection number is related to the quality of HDMI cables and signal source
resolution—good cable or lower source resolution can connect more units. User can also add
HDMI splitter at the front end to increase daisy chain connection number for large scale video
display.
If loop out port is not connected, user can connect to a monitor for signal source monitoring
purpose. HDMI Loop Out port is for daisy chain connection. It is not an input port.
Box ID, RS232 and Ethernet settings can be executed through CH-1 or CH-2. The setting result
will be applied to both channels.
User can control or operate EdgePro settings through Ethernet. Default IP address is
192.168.0.100.
When multiple units are used at the same time, user can set different IP address in each
EdgePro so that each EdgePro can be controlled independently.
6.5
HDMI Loop Out for daisy chain connection
HDMI Loop Out to next EDGEPRO HDMI input port or signal source
6.6
System settings: Box ID, RS232, Ethernet