background image

 

 

Page 4 of 16

 

Nubion Plus

TM

 

AVE-N09-IM 

Issue 01 

INSTALLATION MANUAL 
 

 
 

0.2 

Amendment Record procedure 

 

The master copy of this document shall be kept electronically as a read only 

document under the control of Aveo Engineering Group, s.r.o. as Master Copy.  

ALL

 amendments to this manual will initiate a raise of issue. 

ALL

 raises of issue will be given a sequential numeric issue ident sequentially 

from 01 to 99 in Table 01 - 

Issue No:

 Column– Initial Issue of Document will 

be 

“01”

 

ALL

 Issues of this document will be approved by Head of DO 

 

 

 

 

0.3 

Affected Pages Procedure 

 

ALL pages affected by ANY raise of issue of this document will be listed in Table 

01 - 

Affected Pages 

Column. 

The reason(s) for ALL raise of issue and description of change due to raise of 

issue will be provided for ALL raises of issue in Table 01 - 

Details

 Column. 

Changes from  the previous issue  are highlighted  by  YELLOW  HIGHLIGHTING 

over  new  content.  AND  YELLOW  HIGHLIGHTING  AND  CROSSING  OUT  of 

deleted content.   

Example

 (CROSSING OUT) 

 

 

 

 

 

 

 

 

 

 

 

 

Issue 

No. 

Details 

Date 

Affected 

Pages 

01 

Initial Issue 

03.Sep.2021 

ALL 

 

 

 

 

 

 

 

 

Table 01: Document Amendment Record Table 

Summary of Contents for Nubion Plus

Page 1: ...AVE N09 IM Aveo Engineering Group s r o All rights reserved The information contained within this document must not be disclosed copied or reproduced in whole or in part without prior written permiss...

Page 2: ...PERATING INSTRUCTIONS 5 1 3 INSTALLATION SCHEMATIC WIRING DIAGRAM 6 1 4 CONTROL POWER INPUTS 7 1 5 TECHNICAL SPECIFICATION 7 1 6 TECHNICAL DRAWING 9 1 7 WIRING CHART 10 1 8 OPTIC SIMULATION 11 1 9 EQU...

Page 3: ...r EASA AP429 This installation manual is applicable for part numbers Nubion Plus Landing 8 AVE N09PANSNL 1WP Nubion Plus Landing 15 AVE N09PANSNL 2WP Nubion Plus Taxi 25 AVE N09PANSNT 3WP Nubion Plus...

Page 4: ...Document will be 01 ALL Issues of this document will be approved by Head of DO 0 3 Affected Pages Procedure ALL pages affected by ANY raise of issue of this document will be listed in Table 01 Affect...

Page 5: ...with a low power draw to meet the highest requirements of all certified aircraft Nubion Plus Landing 8 AVE N09PANSNL 1WP Nubion Plus Landing 15 AVE N09PANSNL 2WP Nubion Plus Taxi 25 AVE N09PANSNT 3WP...

Page 6: ...Page 6 of 16 Nubion PlusTM AVE N09 IM Issue 01 INSTALLATION MANUAL 1 3 Installation Schematic Wiring Diagram...

Page 7: ...l Specification Electronic specification Ambient temperature 25 C Operating voltage 9 36V DC Voltage protection a Over voltage protection 80V 1s b Over voltage lockout 38 5V c Under Voltage protection...

Page 8: ...8 U curve G Vibration 8 H curve P R curve E E1 Explosive Atmosphere 9 6 1 A 9 6 2 Waterproofness 10 R Fluids Susceptibility 11 F Sand and Dust 12 D Fungus 13 F Salt Fog 14 T Magnetics Effects 15 Y Po...

Page 9: ...Page 9 of 16 Nubion PlusTM AVE N09 IM Issue 01 INSTALLATION MANUAL 1 6 Technical Drawing dimensions in mm inches...

Page 10: ...1 INSTALLATION MANUAL 1 7 Wiring Chart Use diagram below defining the wiring size depending on the current and the wire length Make sure you add up the current for all connected lights If current is n...

Page 11: ...Page 11 of 16 Nubion PlusTM AVE N09 IM Issue 01 INSTALLATION MANUAL 1 8 Optic Simulation Nubion Plus LANDING 8 PN AVE N09PANSNL 1WP 150 000 cd Nubion Plus LANDING 15 PN AVE N09PANSNL 2WP 60 000 cd...

Page 12: ...Page 12 of 16 Nubion PlusTM AVE N09 IM Issue 01 INSTALLATION MANUAL Nubion Plus TAXI 25 PN AVE N09PANSNT 3WP 15 000 cd Nubion Plus TAXI 45 PN AVE N09PANSNT 5WP 6 500 cd...

Page 13: ...etroleum based product be used to clean the lights 1 11 Testing the Lights before Installation All Aveo Aviation lights undergo rigorous testing prior to being released from our engineering manufactur...

Page 14: ...sts are successfully completed the lights can be installed on the aircraft IMPORTANT NOTES Under no circumstances should any power supply other than a 9 36V DC or a 14 or 28 Volt battery be used to te...

Page 15: ...g Cadmium Cd 0 01 Mercury 0 1 Lead Pb 0 1 Hexavalent chromium Cr6 0 1 Polybrominated biphenyls PBB 0 1 Polybrominated diphenyl ethers PBDE 0 1 Bis 2 Ethylhexyl phthalate DEHP 0 1 added in 2015 Benzyl...

Page 16: ...6 of 16 Nubion PlusTM AVE N09 IM Issue 01 INSTALLATION MANUAL maintenance or service is listed on the current European Chemicals Agency s Candidate list of Substances of Very High Concern for Authoriz...

Reviews: