1.4

 

Control & Power Inputs 

 
RED

    

 

Input Power, AWG 22 

BLACK

  

 

Power Return, AWG 22 

GREEN/YELLOW

 

Chassis, AWG 22 

WHITE

  

 

Master/Slave, AWG 24 

BLUE

   

 

Synchro, AWG 24 

GREEN

  

 

WigWag, AWG 24 

 

1.5

 

Technical Specification 

 

Electronic specification - Ambient temperature (25°C): 

 

Operating voltage:

  

 

9-36V DC 

Voltage protection: 

 

a. Over-voltage protection: 80V/1s 

 

 

 

 

 

b. Over-voltage lockout: 38.5V 
c. Under-Voltage protection: 7V 

Reverse polarity protection:

 

Yes 

LED quantity: 

 

 

6 pcs 

Performance: 

Input current:

 

2.23A @14V DC  

 

 

 

 

 

1.07A @28V DC 

 

 

Input power:

 

31.2W @14V DC 

  

 

 

 

 

29.8W @28V DC 

Operating temperature: 

 

-55°C to +85°C / -67°F to +185°F 

Over-Temperature protection:

  Yes 

Weight:

  

 

 

 

7.48 oz (212 g) 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for Nubion Plus

Page 1: ...AVE N09 IM Aveo Engineering Group s r o All rights reserved The information contained within this document must not be disclosed copied or reproduced in whole or in part without prior written permiss...

Page 2: ...PERATING INSTRUCTIONS 5 1 3 INSTALLATION SCHEMATIC WIRING DIAGRAM 6 1 4 CONTROL POWER INPUTS 7 1 5 TECHNICAL SPECIFICATION 7 1 6 TECHNICAL DRAWING 9 1 7 WIRING CHART 10 1 8 OPTIC SIMULATION 11 1 9 EQU...

Page 3: ...r EASA AP429 This installation manual is applicable for part numbers Nubion Plus Landing 8 AVE N09PANSNL 1WP Nubion Plus Landing 15 AVE N09PANSNL 2WP Nubion Plus Taxi 25 AVE N09PANSNT 3WP Nubion Plus...

Page 4: ...Document will be 01 ALL Issues of this document will be approved by Head of DO 0 3 Affected Pages Procedure ALL pages affected by ANY raise of issue of this document will be listed in Table 01 Affect...

Page 5: ...with a low power draw to meet the highest requirements of all certified aircraft Nubion Plus Landing 8 AVE N09PANSNL 1WP Nubion Plus Landing 15 AVE N09PANSNL 2WP Nubion Plus Taxi 25 AVE N09PANSNT 3WP...

Page 6: ...Page 6 of 16 Nubion PlusTM AVE N09 IM Issue 01 INSTALLATION MANUAL 1 3 Installation Schematic Wiring Diagram...

Page 7: ...l Specification Electronic specification Ambient temperature 25 C Operating voltage 9 36V DC Voltage protection a Over voltage protection 80V 1s b Over voltage lockout 38 5V c Under Voltage protection...

Page 8: ...8 U curve G Vibration 8 H curve P R curve E E1 Explosive Atmosphere 9 6 1 A 9 6 2 Waterproofness 10 R Fluids Susceptibility 11 F Sand and Dust 12 D Fungus 13 F Salt Fog 14 T Magnetics Effects 15 Y Po...

Page 9: ...Page 9 of 16 Nubion PlusTM AVE N09 IM Issue 01 INSTALLATION MANUAL 1 6 Technical Drawing dimensions in mm inches...

Page 10: ...1 INSTALLATION MANUAL 1 7 Wiring Chart Use diagram below defining the wiring size depending on the current and the wire length Make sure you add up the current for all connected lights If current is n...

Page 11: ...Page 11 of 16 Nubion PlusTM AVE N09 IM Issue 01 INSTALLATION MANUAL 1 8 Optic Simulation Nubion Plus LANDING 8 PN AVE N09PANSNL 1WP 150 000 cd Nubion Plus LANDING 15 PN AVE N09PANSNL 2WP 60 000 cd...

Page 12: ...Page 12 of 16 Nubion PlusTM AVE N09 IM Issue 01 INSTALLATION MANUAL Nubion Plus TAXI 25 PN AVE N09PANSNT 3WP 15 000 cd Nubion Plus TAXI 45 PN AVE N09PANSNT 5WP 6 500 cd...

Page 13: ...etroleum based product be used to clean the lights 1 11 Testing the Lights before Installation All Aveo Aviation lights undergo rigorous testing prior to being released from our engineering manufactur...

Page 14: ...sts are successfully completed the lights can be installed on the aircraft IMPORTANT NOTES Under no circumstances should any power supply other than a 9 36V DC or a 14 or 28 Volt battery be used to te...

Page 15: ...g Cadmium Cd 0 01 Mercury 0 1 Lead Pb 0 1 Hexavalent chromium Cr6 0 1 Polybrominated biphenyls PBB 0 1 Polybrominated diphenyl ethers PBDE 0 1 Bis 2 Ethylhexyl phthalate DEHP 0 1 added in 2015 Benzyl...

Page 16: ...6 of 16 Nubion PlusTM AVE N09 IM Issue 01 INSTALLATION MANUAL maintenance or service is listed on the current European Chemicals Agency s Candidate list of Substances of Very High Concern for Authoriz...

Reviews: