Aveo Systems, Inc. • 1791 West Oak Parkway, Suite 8 • Marietta, GA 30062 • Phone: +1.678.653.7090 •
DS-10100-001 Version 2020_01_06
Installation Steps
1
Step
To get started, locate the studs near where
you'd like to install the enclosure before cutting
the drywall. The in-wall backbox is designed to
fit between wall studs.
Once the studs have been located on the left
and right of the desired location, leave at least
13 mm (1/2 in.) clearance from the studs to
ensure mounting clips can rotate and secure the
backbox to the drywall.
Use a level to draw straight lines.
Cut an opening in the drywall with dimensions
300 x 207 mm (11 3/4 x 8 1/8 in.).
300 mm
11 3/4”
207mm
8 1/8”
13 mm, 1/2” minimum
2
Step
Pull and terminate the network cable into the
box through the bottom cut-outs in preparation
for connecting to Mira Connect 10.
Insert the backbox into the hole with the clips
remaining on the inside of the backbox.
Rotate one of the top drywall clips by tightening
the clip screw just enough to secure the box to
the wall. Do not finish tightening.
Repeat this for the opposite top clip, then with
the two bottom clips.
Once the box is secure enough to remain in
position, but not completely tightened, level the
box and tighten the screws so the enclosure is
secure and level.
3
Step
Mount the adapter plate to the back of the Mira
Connect 10 touch panel using four M4 screws
provided.
4
Step
Turn the adapter plate over, connect the
network cable to Mira Connect 10, ensure the
power switch is turned on. Use a Power over
Ethernet (PoE) enabled network connection.
Mount mount the adapter plate to the backbox
using four M4 screws with the Ethernet
connection on the bottom.
5
Step
Install the trim ring by aligning over the opening
and then snapping it into place. The trim ring
can be carefully removed by pulling it from the
backbox.
Trim ring
Finished