RA4000e Series User manual
54
RAID configuration error message:
The following two messages will be displayed alternatively when the
setting of RAID level selectors does not match the existing disk RAID
level setting:
R A I D L e v e l
U
n
m
a
t c
h
e
d
C
u
r
r
e
n
t
:
R
5
O
r
i
g
i
n
a l
:
R
0
The system will stop working until users choose one of the following
options:
Shut down RA4000e Series and tune the RAID level selectors to
R5
Re-plug the four disks and re-create the RAID to R0 (but data in
the R5 disks will be lost)
Fan failure message: fan can not function normally
F
A
N
F
a
i
l
1
0
0
r
p m
Where the speed of failed fan is 100 rpm
Overheat message: will be displayed when temperature > 50
o
C
T e m p e r a t u r
e !
!
5
1
。
C
>
5
0
。
C
Disk shut down message: will be displayed when temperature >
55oC
O v e r T e m p e r a t u r e
D
i
s
k
S h
u
t
d
o
w
n
!