background image

3.6. +RCX remote control system programing

Parallel operation of a few screens with built-in +RCX installed in the same room is possible; in such case control 

systems of each screen must be programmed with dedicated control code. The screen with +RCX remote control system 
is supplied with single remote transmitter, it is possible to purchase optional transmitters. The optional transmitters must be 
programmed at the controller.

A) Setting of the new transmitter
Controller can memorize 10 individual control codes of remote transmitters.

Ÿ

Connect power supply to the screen.

Ÿ

Press 3 times P2 button of the remote transmitter within 12 seconds after the screen’s sound signal. 

Ÿ

Transmitter is not set to the control system with individual code (random generated code).

B) Deleting of the transmitter

Ÿ

Connect power supply to the screen.

Ÿ

Press P2 button of the remote transmitter once.

Ÿ

Press the “Stop” button of the remote transmitter within the next 4 seconds.

Ÿ

Press P2 button within the next 4 seconds again. 

Ÿ

The remote transmitter was deleted from the controller memory.

C) Appending new remote transmitter
New remote transmitter will obtain the same individual control code as the original one when appended, or new 

individual control code if set. We suggest appending new remote transmitters in case some screen with +RCX control 
systems (or controlled with DRC control systems) are installed in the near neighbourhood (transmitter operation range). 

Ÿ

Connect power supply to the screen.

Ÿ

Press P2 button of the original remote transmitter twice.

Ÿ

Press P2 button of the new remote transmitter once within the next 4 seconds . 

Ÿ

Appending of the new remote transmitter is done.

D) Converting direction
It is possible to convert direction of the operation of the remote transmitter buttons, i.e. the “



” button will cause the 

screen to roll out instead of causing the screen to roll inn, and the “

” button will cause the screen to roll inn instead of 

causing the screen to roll out.

Ÿ

Connect power supply to the screen.

Ÿ

Press P2 button of the remote transmitter once.

Ÿ

Press the “

” button of the remote transmitter within the next 4 seconds once. 

Ÿ

Press P2 button of the new remote transmitter once within the next 4 seconds once.

Ÿ

Converting direction is done.

3.7 triggered control system programming

triggered control systems radio frequency connection between transmitter and controller is coded with individual 
control code. Coding of the control system can be performed during screen production at the Avers factory only. You can 
find information about the individual number of control code of your screen at the transmitter enclosure. Parallel operation 
of a screens with built-in control systems is possible without any problem, if the screen’s control systems are 
programmed with different individual control codes (for individual screen control) or the screen’s control systems are 
programmed with the same individual control code (for group screen control). 

Screen operation

Projection screen AVERS can be operated manually or automatically

- Press “POWER” button at the projector’s remote control transmitter or at the projector itself. Projector lamp will light on, 
  the screen will begin rolling out and it will stop automatically when the bottom bar will reach the bottom position.
- Press  “POWER” button at the projector’s remote control transmitter or at the projector itself. Projector lamp will light off, 
  the screen will begin rolling in and will stop automatically when the bottom bar will reach the upper position.

4. 

 (screens with built-in triggered control 

system). Both operation methods can be used simultaneously if optional dedicated wall switch is installed.  

4.1 Automatic operation 

 (screens with control system)

Automatic screen operation is provided with use of the triggered signal radio frequency transmitter. 

 9

 IMPORTANT!
Do not decrease (tuning knob 1+) the range of the rolled down surface. It can damage the screen.
Do not increase (regulation 2+)  the  range of the surface which was rolled down behind the STOP mark, placed in 
the upper right corner of the screen. Rolling down the screen  behind the mark can damage the screen.

Summary of Contents for Solar

Page 1: ...Electric projection screen Avers Solar User s manual Read these instructions carefully before operating the screen ...

Page 2: ...the most performance and enjoyment of your new screen Enjoy time with the Avers Screens product SAFETY INFORMATION NOTICE Important safety information Follow the instructions described in the operating manual for safety reasons After reading the manual please store it in a safe place just in case you need it in the future NOTICE THE DEVICE HAVE TO BE EARTHED WARNING 1 Disconnect the device from th...

Page 3: ...o not do anything that may damage the power cable or power plug Do not damage the power cable make any modifications by your own put it near the hot objects bend it strongly twist it pull out the power cable put the heavy objects on the cable wrap it into the bundle Operation of the screen with damaged power cord can result with electric shock electric short circuit and fire Do not touch the power...

Page 4: ...accessories Wall control switch x 1 x 2 x 2 Installation brackets Regulation wrench x 1 Trigger transmitter x 1 Operation manual x 1 4 2 2 Technical Data Projection fabrics characteristics Matt White P MWP a special screen dedicated polyester fabric double side covered with vinyl black back surface and white front projection surface recommended for application with DLP and LCD multimedia projector...

Page 5: ...tt White P fabrics Motor Electric tubular engine AC Voltage Power consumption Rotation speed rot min Torque Max operation time Engine single cycle operation time operation cycle can be repeated in 20 minutes intervals Dimensions Power supply 220 240V AC 50 Hz 292 W 40 Nm 1 29A 15 4 min RF remote controller Triggered transmitter Dimensions 110 x 58 x 20 mm 90 x 58 x 65 mm Power supply 1 x 12V batte...

Page 6: ...lts to the lock position 4 see Picture see Picture The mounting screws diameter should be not smaller than Ø8 mm In case of the cartboard plaster ceiling installation use cartboard plaster dedicated steel anchors with Ø11mm diameter screws The mounting screws diameter should be not smaller than Ø8 mm In case of the cartboard plaster walls installation use cartboard plaster dedicated steel anchors ...

Page 7: ...een power line during installation work Manual wall steering switch should be installed at the place meeting the following conditions a installation150 180 cm above the floor level b the screen should be visible by the wall switch operator during the screen operation c wall switch operator cannot stay in reach of any of the screen s moving parts during the screen operation d the wall switch must b...

Page 8: ...wn live N blue neutral G yellow green protective bl yg bk br Programing the length of the rolled out screen screen bottom bar position Roll up the screen until it will stop automatically in the upper position Insert regulation wrench included in the screen set into the regulation slot see picture 6 located in the left bottom part of the screen Regulation knob 2 bottom enables setting of the lower ...

Page 9: ...supply to the screen Press P2 button of the remote transmitter once Press the button of the remote transmitter within the next 4 seconds once Press P2 button of the new remote transmitter once within the next 4 seconds once Converting direction is done 3 7 C12VRC triggered control system programming C12VRC triggered control systems radio frequency connection between transmitter and controller is c...

Page 10: ...jection screen Avers do not require periodical service maintenance Clean dust from the screen case and fabrics with dry soft cloths If needed use moisturized cloth with soft detergent to remove stains After stain removal dry the cleaned surface with cloth carefully 4 4 Before calling the service The screen fabrics does not roll down up automatically Projector power cord plug is not connected to th...