Setting the Start Encode Position
This option only appears in the Advanced Setup menu. The start encode position is
only
used in non-stop encode mode
. The printer uses this initial starting position to look for
the RFID inlay to program while moving the supply. The range is 10 to 2000. The default
is 100.
The start encode position is measured from the leading edge of the supply to the
beginning of the RFID inlay encoding area in 0.01 inches.
The start encode position must “lead” (be before) the first TID position; otherwise, error
737 occurs.
Use the
RFID Printer Setup Utility
to determine the start encode position then enter the
value at the printer.
Select
To
Decrease the setting.
Increase the setting.
Press
1
to toggle the amount (1, 10, or 100).
Start Encode Position
Trailing Edge
0,0 point
Leading Edge
Summary of Contents for Monarch ADTP1
Page 10: ...1 4 System Administrator s Guide Classification Avery Dennison Public...
Page 24: ...2 14 System Administrator s Guide Classification Avery Dennison Public...
Page 28: ...3 4 System Administrator s Guide Classification Avery Dennison Public...
Page 50: ...6 16 System Administrator s Guide Classification Avery Dennison Public...
Page 54: ...7 4 System Administrator s Guide Classification Avery Dennison Public...
Page 74: ...10 4 System Administrator s Guide Classification Avery Dennison Public...
Page 84: ...11 10 System Administrator s Guide Classification Avery Dennison Public...
Page 88: ...A 4 System Administrator s Guide Classification Avery Dennison Public...
Page 90: ...B 2 System Administrator s Guide Classification Avery Dennison Public...
Page 93: ......