ZM201 Indicator User Instructions
53
8.3 Counting application supervisor menu
2.
Press
UNITS
…
count
is displayed. Use this to set the items relating to counting:
l
Enable/Disable the ability to print the accumulated total (
Prt tot
).
l
Key in a print format number for printing the total accumulated
information (
tot FMt
).
l
Enable/Disable the ability to clear the total accumulation information
when the total is printed (
clr tot
).
l
Reset the accumulator memory channel value to 0 (
rESEt
).
The following steps describe the procedure to set these items.
Print total
Count
Print Total
3.
From
count
, press
SELECT
…
Prt tot
is displayed. This stands for print total.
4.
Press
SELECT
…
oFF
is displayed.
5.
Press
ZERO
to keep the print total function disabled or press
UNITS
to toggle
to
on
and press
ZERO
to enable printing of the accumulated total …
Prt tot
is displayed.
If enabled, during normal operation the user can press and hold
for three seconds and the selected total print format (see step
8
below)
will be sent out any port that is set up to print. The display will flash
Prn-
tot
.
Total format
Count
Print Total
Total Format
6.
Press
UNITS
…
tot FMt
is displayed. This stands for the total print format.
7.
Press
SELECT
…
The current print format number is displayed with a flashing right-most
digit. (Default is format 8)
8.
Press
ZERO
to accept the existing setting or key in a new format number and
press
ZERO
…
tot FMt
is displayed.