ZM201 Indicator User Instructions
55
8.4 Checkweighing application supervisor menu
8.4 Checkweighing application supervisor menu
Figure 8.4
shows the Supervisor menu when you are in the Checkweighing application:
Figure 8.4 Supervisor menu for the Checkweighing application
Follow these steps to set the items in the Supervisor menu.
8.4.1 Check
Super
Setpoint
Check
1.
With the Checkweighing application active, access the Supervisor menu using
password 1793. Refer to
Accessing the menus on page 29
for instructions.
From
SuPEr
, press
SELECT
…
SEtPnt
is displayed.
2.
Press
UNITS
…
chEcK
is displayed. This stands for checkweigher. Use this to set the
items relating to checkweighing:
l
Set under divisions for acceptable target weight (
undrdiv
)
Undrdiv
Overdiv
Check
Super
Setpnt
Edit
Reset
No
Yes
Reset
No
Yes
Battery
Enable
Tmout
Off
On
Port 1
Port 2
Out1
Out2
Out3
In1
In2
In3
None
Units
Select
Tare
Zero
F1
Accu
PrntHld
User
Off
On
Annun
Bold
boxes and text
denote defaults.
1-3600
minutes
0-100
0-100
Key
in
value
Key
in
value
Key
in
value
SELECT
=
TARE
=
=
UNITS
=
ZERO
=
F1
= Escape or
The
Setpnt
and
bAttErY
submenus in
Figure 8.4
are the same as described in
General Weighing application supervisor menu on page 44
. Go there for information
on those submenus. The unique submenus to this application are described below.