3.2 Accumulator application
3.2 Accumulator application
This section applies if the Accumulator application is active.
3.2.1 SELECT key default function
In the Accumulator application you can view the Gross, Net, Tare, Gross Total, Net
Total and Transaction Count display values by repeatedly pressing
SELECT
.
When the Gross Total is displayed, both the
GROSS
and
QTY
annunciators will be lit.
When the Net Total is displayed, both the
NET
and
QTY
annunciators will be lit. When
the Transaction Count is displayed, the
QTY
annunciator is lit.
3.2.2 Special key functions
The following key has an extra function in this application:
F1
Press
F1
and the active accumulator channel (
chAn X
) appears. Scroll
through the list of channels (
chAn 1
-
chAn 10
), using
or
UNITS
.
Press
ZERO
to activate that channel.
3.2.3 Accumulator operation
The accumulator application can be used to record totals of individual weighments.
Follow these steps:
1.
Press
ZERO
to zero the scale, if necessary …
0
is displayed.
2.
Place item on the scale …
Weight is displayed.
You can use gross or net weighing with the accumulator application as it stores both
gross and net totals. You have 10 accumulator channels that can be used to store
totals for up to 10 separate products.
F1
accesses the different channels for accumulating data. Pushbutton tare is
available for the current channel.
Each accumulator channel has it's own individual gross, tare and net totals,
transaction counter and an ID, if entered.
Press
SELECT
to toggle through the current values. When annunciators QTY &
GROSS are lit, this indicates the total for the gross value. When annunciators QTY &
NET are lit this indicates the total for the net value. When annunciators QTY & TARE
are lit this indicates the total for the tare value. When QTY only is lit this is the current
number of transactions.