2. INSTALLATION INSTRUCTIONS
TOOLS NEEDED TO INSTALL THE RANGE HOOD
Phillips screwdriver
Hammer and flat blade screwdriver
Sheet metal sheers
Pair of pliers
Scissors (to cut duct tape)
Metal foil duct tape
Marker or pencil
Level
Measuring tape
BEFORE INSTALLING THE HOOD
For the most efficient airflow exhaust, use a straight run or as few elbows as possible.
Vent unit to the outside only.
Two (2) people are required for installation.
Remove the range hood from the carton packaging and place it on a flat surface for assembly.
ELECTRICAL REQUIREMENTS
CAUTION: THIS APPLIANCE SHOULD BE PROPERLY GROUNDED.
This hood must be power supplied from a 110-120 V, 60 Hz source and connected to an
individual, properly grounded circuit (3-prong outlet).
If the electrical supply does not meet above requirements, call a licensed electrician before
proceeding.
Route house wiring as close as possible to the installation location, in the ceiling or back wall.
The hood must be connected to the house wiring in accordance with the local codes and
norms.
WALL FRAMING FOR ADEQUATE SUPPORT
This vent hood is heavy. Adequate structure and support must be provided in all types of
installations. If mounting on dry wall, the hood must be secured to vertical studs in the wall or to
a horizontal support.
19