background image

AO16 Analog Output Card

12

Safety Compliance

Safety Statement

This equipment has been tested to comply with USA and Canadian safety 
certification in accordance with the specifications of UL Standards: UL60065 7th 
/IEC 60065 7th and Canadian CAN/CSA C22.2 60065:03. Avid Inc., has been 
authorized to apply the appropriate UL & CUL mark on its compliant equipment.

Warning

Important Safety Instructions

1) Read these instructions.

2) Keep these instructions.

3) Heed all warnings.

4) Follow all instructions.

5) Do not use this equipment near water.

6) Clean only with dry cloth.

7) Do not block any ventilation openings. Install in accordance with the 
manufacturer’s instructions.

8) Do not install near any heat sources such as radiators, heat registers, stoves, 
or other equipment (including amplifiers) that produce heat.

9) Do not defeat the safety purpose of the polarized or grounding-type plug. A 
polarized plug has two blades with one wider than the other. A grounding type 
plug has two blades and a third grounding prong. The wide blade or the third 
prong are provided for your safety. If the provided plug does not fit into your 
outlet, consult an electrician for replacement of the obsolete outlet.

10) Protect power cords from being walked on or pinched particularly at plugs, 
convenience receptacles, and the point where they exit from the equipment.

11) Only use attachments/accessories specified by the manufacturer.

12) For products that are not rack-mountable: Use only with a cart, stand, tripod, 
bracket, or table specified by the manufacturer, or sold with the equipment. 
When a cart is used, use caution when moving the cart/equipment combination 
to avoid injury from tip-over.

13) Unplug this equipment during lightning storms or when unused for long 
periods of time. 

14) Refer all servicing to qualified service personnel. Servicing is required when 
the equipment has been damaged in any way, such as power-supply cord or 
plug is damaged, liquid has been spilled or objects have fallen into the 
equipment, the equipment has been exposed to rain or moisture, does not 
operate normally, or has been dropped.

15) For products that are a Mains powered device: 
The equipment shall not be exposed to dripping or splashing and no objects 
filled with liquids (such as vases) shall be placed on the equipment. 

Warning! To reduce the risk of fire or electric shock, do not expose this 
equipment to rain or moisture. 

16) For products containing a lithium battery: 
CAUTION! Danger of explosion if battery is incorrectly replaced. Replace only 
with the same or equivalent type. 

17) For products with a power switch: 
The main power switch should remain accessible after installation. 

18) The equipment shall be used at a maximum ambient temperature of 40° C.

Summary of Contents for AO16

Page 1: ...PN 9320 65060 00 REV A 2 12 AO16 Analog Output Card for VENUE Systems...

Page 2: ...axim Mbox MediaComposer MIDI I O MIX MultiShell Nitris OMF OMF Interchange PRE ProControl Pro Tools M Powered Pro Tools Pro Tools HD Pro Tools HD Native QuickPunch Recti Fi Reel Tape Reso Reverb One R...

Page 3: ...Guide 2 About www avid com 2 Chapter 2 Installing AO16 3 Installing in Mix Rack 3 Installing in SC48 4 Completing and Confirming Installation for Mix Rack and SC48 5 Installing in Stage 48 6 Chapter 3...

Page 4: ...AO16 Analog Output Card iv...

Page 5: ...owing 16 channels of analog line level outputs via XLR 3 male connectors 24 dBu maximum output level System Requirements One of the following is required to use the AO16 card with your installed and c...

Page 6: ...ut how you can learn in a classroom setting at a certified Avid training center Products and Developers Learn about Avid products download demo software or learn about our Devel opment Partners and th...

Page 7: ...he Mix Rack 2 Disconnect all cables from Mix Rack 3 Remove Mix Rack s front panel cover by unscrewing its mounting screws 1 Phillips 4 On the back panel of Mix Rack locate the output slot as noted in...

Page 8: ...d E A stan dard SC48 console ships with one AO16 card installed in slot D A second AO16 can be installed in slot E of the console To install an AO16 card in SC48 1 Shut down your system and turn off p...

Page 9: ...er and any audio cables to your system 2 Turn on your system 3 In VENUE go Option Devices tab view your system hard ware status The newly installed AO16 Card should be dis played 4 Go to Patchbay Outp...

Page 10: ...into and remove the card slot covers 4 Remove the ten back panel mounting screws 5 Carefully pull the panel partially away from the rack making sure not to damage the fan cable attached to the back p...

Page 11: ...op slot of Stage 48 use the ca ble that is labeled in Figure 19 as 1 For a card installed in the middle slot use the cable that is labeled in Figure 19 as 2 For a card installed the bottom slot use th...

Page 12: ...AO16 Analog Output Card 8...

Page 13: ...150 Ohm source impedance and 600 Ohm load impedance unless otherwise specified 0 dBU 0 775Vrms AO16 Analog Line Outputs Parameter Specifications Limit Units Condition Comment Type Balanced XLR3 Male...

Page 14: ...AO16 Analog Output Card 10...

Page 15: ...gulations Cet appareil num rique de la classe B respecte toutes les exigences du R glement sur le material brouilleur du Canada CE Compliance EMC and Safety Avid is authorized to apply the CE Conformi...

Page 16: ...plugs convenience receptacles and the point where they exit from the equipment 11 Only use attachments accessories specified by the manufacturer 12 For products that are not rack mountable Use only w...

Page 17: ...ro Serra Boulevard Daly City CA 94014 3886 USA Technical Support USA Visit the Online Support Center at www avid com support Product Information For company and product information visit us on the web...