background image

B - PRODUCT DESCRIPTION

B1 - PHOTOCELLS

1

2

3

 1

 

Reception photocell RX 

 2

 

Transmission photocell TX

 3

 

Lens of the infrared beam

C - INSTALLATION

C1 - SET OF PHOTOCELLS

• 

Read the label on the back to identify the transmission photocell (TX) and 
the reception photocell (RX)

•  Install the reception photocell (RX is indicated on the back) on the side 

with the control box or the motor containing the electronic control board. 
The surface of the posts must be perfectly flat in order to properly align 
the infrared beam of the photocells.

•  Place the photocells at exactly the same height from the ground; they 

must be perfectly aligned and parallel to each other.

 

The distance between the outer side of the gate and the photocells must 
be between 10cm and 15cm.

•  Mount the photocells on the posts.

30cm min
60cm max

Outer side of the property

view from above

Inner side of the property

precise alignment

10cm min

15cm max

Take note: place a silicone seal between the pillar and the photocells 

as well as at the output of the power cable.

CONTENTS OF THE KIT

x 1

x 6

x 6

x 4

A - SAFETY INSTRUCTIONS

A1 - OPERATING PRECAUTIONS 

•  Read this entire manual before starting the installation.
•  Do not allow children to operate the product.

A2 - SERVICING AND CLEANING

•  Use a soft, slightly damp cloth to clean your product.
•  All electrical connections must be performed with the power switched 

off (safety switch in OFF position) and battery disconnected.

•  Do not use abrasive or corrosive substances.
•  Do not spray any products directly onto the unit.
•  In winter, scrape off the frost which may have formed on the lenses. 

A3 - RECYCLING

This logo denotes that devices which are no longer in use 
must not be disposed of as household waste. They are likely 
to contain hazardous substances that are dangerous to both 
health and the environment. Return the equipment to your 
local distributor or use the recycling collection service 
provided by your local council.

Pour en savoir plus : 
www.quefairedemesdechets.fr

Take care not to put silicone on the base of the photocell to avoid 

condensation of the product.

45mm

20mm

Outer side of the property

C2 - SET OF PHOTOCELLS

When used with a non-visible gate, it is mandatory to
install a second set of photocells to prevent the
gate from opening when an object (a car, person, etc.) is behind the gate.
•  The photocells must be perfectly aligned and parallel to each other.
•  The reception photocells (RX indicated at the back) must be installed at 

the same side of the gate as the electronic control box.

•  The photocells must be installed on the inner side of the property. The 

distance between the main edges of the gate in an open position at 90° 
and the photocells must be between 10cm and 15cm maximum.

•  The mounts used to secure the photocells must be correctly secured to 

the ground and precisely aligned.

•  The photocells must be placed exactly at the same height from the 

ground, and the height must be between 30cm and 60cm.

pair 1

pair 2

TX2

TX1

RX1

90°

90°

RX2

Inner side of the property

View from above

10cm min / 15cm max

30cm min
60cm max

D - CONNECTIONS

The photocells are connected differently depending on the type of motor 

specification:

- For the electric operation of sliding gates, see section D1
- For the electric operation of swing gates, see section D2

Disconnect the removable terminal block, connect the photocell wires to 
the terminal block as shown in the diagram below and then reconnect the 
terminal block.

D1 - CONNECTION FOR THE ELECTRIC OPERATION OF 

SLIDING GATES

•  1 set of photocells

By connecting the photocells in this way, the system reacts to a break of the 
infrared beam only during closing.

+

12V

HALL

GN

D

M1

~- ~+

~+

~-

NO COM NC

Transmission 
photocell 
TX1

Reception 
photocell 
RX1

•  2 sets of photocells

By connecting the photocells in this way, the system reacts to a break of 
one or the other infrared beams only during closing.

+

12V

HALL

GN

D

M1

~- ~+ NO COM NC

~- ~+

~+

~-

NO COM NC

~+

~-

Reception 
photocell RX1

Transmission 
photocell TX1

Reception pho-
tocell RX2

Transmission 
photocell TX2

V3

PHOTOCELLS

12/24V DC

EN

Ref. 114359

Reviews: