EX5000 Release 8.2.2 Installation Manual P/N 600-00073-001 Rev 02
- 53 -
2.
Set the following options:
•
Sensor—
GTX 345
•
Port—
Select the MFD ARINC 429 port to which the GTX-345 Receiver is wired (Port 3
shown for example)
3.
When you are done, press
Save
. Press
Cancel
to exit without saving changes.
4.
Changes do not take effect until the MFD has been restarted. From the Maintenance Mode Page,
press
Restart System
. If needed, see Table 20: Traffic Messages.
5.8.5 ADS-B Weather Interface Checkout
To test the ADS-B weather interface:
1.
After Setup is complete boot the MFD into flight mode and go to to the Aux page. Verify the
following message is displayed: “FIS-B Receiver is Operating Normally”.
5.8.6 ADS-B Traffic Interface Checkout
To test the ADS-B traffic interface:
After Setup is complete boot the MFD into flight mode and go to the Aux page. Verify the following
message is displayed: “Traffic Sensor is Operating Normally”