Invalid Sensors and Error Conditions
600-00157-000 Rev. 06
-61-
Entegra EXP5000 PFD
4.4 Warmstart Conditions
The EXP5000 is capable of performing a warmstart from a fully
aligned condition when subjected to a power loss of less than 30
seconds. In this event, the “PLEASE STANDBY” message in the
warmup box is displayed for approximately 2 seconds followed by the
“ATTEMPTING QUICK RESTART” message and its countdown.
There is no requirement to limit dynamic maneuvering during this
warmstart attempt.
Figure 17. Quick Restart Messages
Note:
Two warmstart attempts in a row without a successful alignment
between attempts will result in a full alignment attempt.