IFD5XX Installation Manual
600-00299-000
Page 176 of 198
Revision: 02
IFD 540 #1
5
24
23
46
47
48
49
48
49
46
47
24
23
ASPEN EFD1000
429 VLOC RX2A
429 VLOC RX2B
429 GPS RX1A
429 GPS RX1B
EFD429 TX1A
EFD429 TX1B
429 GPS RX3A
429 GPS RX3B
VLOC RX4A
VLOC RX4B
P1
18
19
16
17
26
27
20
21
22
23
P1006
P1001
VOR/ILS ARINC 429 OUT A
VOR/ILS ARINC 429 OUT B
GPS ARINC 429 OUT A
GPS ARINC 429 OUT B
ARINC 429 RX A
ARINC 429 RX B
ARINC 429 RX A
ARINC 429 RX B
GPS ARINC 429 OUT A
GPS ARINC 429 OUT B
VOR/ILS ARINC 429 OUT A
VOR/ILS ARINC 429 OUT B
NOTES:
1. ALL WIRES TO BE 24 AWG OR GREATER UNLESS OTHERWISE NOTED.
2.
AT IFD540 UNIT, TERMINATE SHIELD GROUNDS TO THE CONNECTOR BACKSHELL OR USE CARD-EDGE
CONNECTOR TO TERMINATE SHIELD GROUNDS TO BACK PLATE.
3.
WIRE HARNESS OVERBRAID IS NOT SHOWN BUT MAY BE REQUIRED.
4.
REFER TO MANUFACTURER’S DOCUMENTATION FOR COMPLETE PINOUT AND INTERCONNECT INFORMATION.
IF THE GPS ARINC 429 IN 1 PORT (P5001-48 AND -49) IS ALREADY USED FOR ANOTHER PURPOSE, THE GPS ARINC 429
IN 2 PORT (P5001-50 AND -51) MAY BE CONNECTED INSTEAD.
6.
REFER TO MANUFACTURER’S INSTALL MANUAL FOR AIRDATA CONNECTION.
IFD 540 #2
5
P1001
P1006
5
Figure D - 37: Aspen EFD1000 Interconnect